This OEM igniter (sparker), part 1184216, is the ignition component for the ICP / Tempstar / Heil RGS180HRCA0AAAA gas furnace. The igniter generates the spark or hot surface needed to light the burner gas at the start of each heating cycle. It is one of the most failure-prone parts in a furnace because it is repeatedly heated and cooled, eventually cracking or losing the ability to ignite. Typical failure symptoms include no ignition and no heat, a furnace that clicks or sparks but never lights, repeated lockouts after several failed ignition attempts, or a visibly cracked, chipped, or carbon-fouled igniter element.

Specifications

Spec Value
OEM Part Number 1184216
Type Igniter / Sparker
Brand ICP / Tempstar / Heil
Function Burner Ignition
Application Gas Furnace
Fitment OEM Replacement

Compatibility

Direct-fit replacement for the ICP / Tempstar / Heil RGS180HRCA0AAAA and related RGS-series furnaces that use OEM igniter 1184216.

Installation Guide

  1. Safety First — Disconnect power and shut off the gas supply; verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter position and wiring before removal.
  4. Remove — Disconnect the igniter lead and remove the mounting screw(s); handle the old igniter only by its ceramic base.
  5. Install — Mount the new igniter without touching the element with bare fingers, then reconnect the lead.
  6. Test — Restore gas and power and verify a clean ignition on the next heat call.

Signs You Need a Replacement

  • No heat — furnace won't ignite the burners
  • Furnace locks out after repeated ignition attempts
  • Visible cracks or chips in the igniter element
  • Carbon buildup or discoloration on the igniter

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS180HRCA0AAAA — OEM Ignition | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS180HRCA0AAAA — OEM Ignition | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS180HRCA0AAAA — OEM Ignition | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online