Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface / Spark Igniter 1184216 for RGS180LECA0AAAA | Ships Today
ICP

ICP Hot Surface / Spark Igniter 1184216 for RGS180LECA0AAAA | Ships Today

SKU: 1184216 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM ICP igniter (sparker), part number 1184216, for the ICP Tempstar Heil RGS180LECA0AAAA gas furnace. The igniter creates the spark that lights the burners each time the furnace receives a heat call. When an igniter fails, the furnace draft inducer and gas valve may sequence normally but the burners never light — leaving you with no heat, a unit that locks out after several failed ignition attempts, or visible cracking/erosion of the igniter tip.

Specifications

Spec Value
Part Number 1184216
Type Spark Igniter / Sparker
Brand ICP / Tempstar / Heil
Application Gas furnace burner ignition
Function Ignites burners on heat call

Compatibility

Direct-fit OEM replacement for the ICP Tempstar Heil RGS180LECA0AAAA and related ICP-family furnaces originally equipped with igniter 1184216. Confirm the part number and mounting orientation against the igniter you are removing, since igniter geometry is model-specific.

Installation Guide

  1. Safety First — Shut off gas and disconnect power; verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment access panel.
  3. Document — Photograph the igniter position, gap, and wiring before removal. Avoid touching the new igniter element with bare fingers.
  4. Remove — Disconnect the igniter lead and unfasten the old igniter from its bracket.
  5. Install — Mount the new igniter at the correct position/gap and reconnect the lead per your photo.
  6. Test — Restore gas and power, then run a heat cycle and confirm the burners light promptly and reliably.

Signs You Need a Replacement

  • No heat — burners fail to ignite on a call
  • Furnace locks out after repeated ignition attempts
  • Cracked, eroded, or broken igniter element
  • Delayed ignition or rough light-off

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS180LECA0AAAA | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS180LECA0AAAA | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS180LECA0AAAA | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online