Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Ignitor Electrode for RGS300STEA0AAAA — OEM 1179966 | Ships Today
ICP

ICP Hot Surface Ignitor Electrode for RGS300STEA0AAAA — OEM 1179966 | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM ignitor electrode for the ICP / Tempstar / Heil RGS300STEA0AAAA, ICP part number 1179966. The ignitor is the heart of the furnace's ignition sequence: when the control board calls for heat, the element heats to a glowing temperature and lights the gas at the burners. Ignitors are fragile and degrade with every heating cycle — the element becomes brittle, develops hairline cracks, and eventually fails to reach ignition temperature. A failed ignitor is the most common cause of a furnace that runs its inducer and clicks the gas valve but produces no flame, leaving the home with no heat. Replacing a worn ignitor restores reliable, on-demand ignition.

Specifications

Spec Value
Part Number 1179966
Type Ignitor Electrode
Brand ICP / Tempstar / Heil
Supply 120 VAC element
Fitment OEM Direct Replacement

Compatibility

A direct OEM replacement for ICP, Tempstar, Heil, and Comfortmaker furnaces on the RGS300 platform, including model RGS300STEA0AAAA. Match ICP part 1179966 and verify the bracket and connector orientation before installing.

Installation Guide

  1. Safety First — Disconnect power and shut off the gas, then verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the ignitor position and wiring before disconnecting.
  4. Remove — Unplug the connector, remove the mounting screw, and lift the old ignitor out — handle only by the ceramic base, never the element.
  5. Install — Mount the new ignitor without touching the element, then reconnect the harness per your photo.
  6. Test — Restore power and gas, then watch a full cycle to confirm the ignitor glows and the burners light.

Signs You Need a Replacement

  • Furnace cycles the inducer and gas valve but never lights.
  • Visible cracks or a broken element on the ignitor.
  • Ignitor that no longer glows during a heat call.
  • Repeated lockouts after several failed ignition attempts.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS300STEA0AAAA — OEM 1179966 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS300STEA0AAAA — OEM 1179966 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS300STEA0AAAA — OEM 1179966 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.