Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Ignitor Electrode for RGS300SFEA0AAAA – OEM Igniter | Ships Today
ICP

ICP Hot Surface Ignitor Electrode for RGS300SFEA0AAAA – OEM Igniter | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM ignitor electrode, ICP part number 1179966, for ICP, Tempstar, and Heil gas furnaces. The igniter is the heart of the ignition sequence: on a call for heat the control board energizes the electrode, which glows hot enough to light the burner gas. Igniters are a wear item — the brittle element cracks with thermal cycling and eventually fails open, leaving the furnace unable to light. Symptoms include a furnace that cycles the inducer and gas valve but never ignites, or one that locks out after several failed ignition attempts.

Specifications

Spec Value
Part Number 1179966
Type Hot Surface Ignitor Electrode
Brand ICP / Tempstar / Heil
Function Ignites burner gas on call for heat
Fitment OEM Direct Replacement

Compatibility

Direct-fit OEM replacement for the ICP / Tempstar / Heil RGS300SFEA0AAAA furnace and other RGS-family models that originally shipped with part 1179966. Confirm against your unit's parts breakdown before ordering.

Installation Guide

  1. Safety First – Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter. Shut off the gas supply.
  2. Access – Remove the burner compartment door.
  3. Document – Photograph the igniter position and wiring routing before removal. Never touch the new element with bare fingers — skin oils shorten its life.
  4. Remove – Unplug the igniter connector and remove the mounting screw(s), then withdraw the old igniter.
  5. Install – Seat the new igniter in the same position, secure it, and reconnect the harness per your photo.
  6. Test – Restore gas and power, then run a heat cycle and confirm the igniter glows and lights the burners.

Signs You Need a Replacement

  • Furnace runs the inducer and opens the gas valve but never ignites
  • Igniter element is cracked, blistered, or no longer glows
  • Repeated ignition lockouts after several attempts
  • No continuity across the igniter when tested cold

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS300SFEA0AAAA – OEM Igniter | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS300SFEA0AAAA – OEM Igniter | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS300SFEA0AAAA – OEM Igniter | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.