Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter with Wiring Kit for RGS150HFAA0AGAA – OEM | Ships Today
ICP

ICP Hot Surface Igniter with Wiring Kit for RGS150HFAA0AGAA – OEM | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM hot surface igniter (part 1171306) bundled with its wiring/harness kit (part 1188370) for the ICP / Tempstar / Heil RGS150HFAA0AGAA gas furnace. The hot surface igniter is the element that heats to a glowing temperature on a call for heat and ignites the gas at the burners — replacing older standing-pilot systems. It is a wear item: every ignition cycle thermally stresses the brittle element, and over time it cracks or loses its ability to reach ignition temperature, causing intermittent or failed heating. The included wiring kit ensures a clean, correct electrical connection during replacement.

Specifications

Spec Value
Part Numbers 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot surface igniter
Brand ICP (Tempstar / Heil)
Voltage 120V
Fits Model RGS150HFAA0AGAA
Application Gas furnace burner ignition

Compatibility

Designed for the ICP RGS150HFAA0AGAA and related RGS150 gas furnaces sold under the Tempstar, Heil, and Comfortmaker brands. Verify the igniter and wiring kit part numbers against your unit's parts list before ordering. Handle the ceramic element by its mounting base only — finger oils and impacts shorten its life.

Installation Guide

  1. Safety First – Disconnect power at the breaker and verify zero voltage with a multimeter; allow the furnace to cool before working.
  2. Access – Remove the burner compartment access panel.
  3. Document – Photograph the igniter position, gasket, and wiring connector before removal.
  4. Remove – Disconnect the igniter harness and remove the mounting screw(s); lift out the old igniter without touching the ceramic element.
  5. Install – Mount the new igniter so the element sits correctly in the burner flame path, then connect the new wiring kit.
  6. Test – Restore power, initiate a heat call, and confirm the igniter glows and lights the burners within the normal ignition sequence.

Signs You Need a Replacement

  • Furnace clicks but burners fail to light (no ignition).
  • Visible crack, blistering, or break in the ceramic element.
  • Intermittent heating or repeated ignition-lockout faults.
  • Igniter glows weakly, unevenly, or not at all.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS150HFAA0AGAA – OEM | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS150HFAA0AGAA – OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS150HFAA0AGAA – OEM | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online