Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter with Wiring Kit for RGS120HTAA0AGAA — OEM 1171306 | Ships Today
ICP

ICP Hot Surface Igniter with Wiring Kit for RGS120HTAA0AGAA — OEM 1171306 | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (part number 1171306), supplied with the matching igniter wiring kit (1188370), is the ignition source for the ICP / Tempstar / Heil RGS120HTAA0AGAA gas furnace. On a call for heat, the control board sends line voltage to the igniter; its silicon-carbide or silicon-nitride element glows white-hot and lights the burner gas. Hot surface igniters are brittle and degrade with every heat cycle — the element develops micro-cracks, draws less current, and eventually fails to reach ignition temperature. The included wiring kit lets you renew the harness and connector at the same time, eliminating intermittent no-heat faults caused by a melted or corroded plug.

Specifications

Spec Value
Igniter Part Number 1171306
Wiring Kit Part Number 1188370
Type Hot surface igniter
Brand ICP / Tempstar / Heil
Application Gas furnace burner ignition
Fitment OEM exact-fit

Compatibility

Designed for the ICP Tempstar Heil RGS120HTAA0AGAA furnace and other ICP-family units (Comfortmaker, Arcoaire) specifying igniter 1171306. The wiring kit 1188370 matches the OEM connector — confirm both part numbers against your unit before ordering.

Installation Guide

  1. Safety First — Turn off gas and disconnect electrical power. Verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner compartment door.
  3. Document — Photograph igniter position and the wiring routing before removal. Handle the new igniter by its body only — never touch the element.
  4. Remove — Disconnect the igniter plug, remove the mounting screw, and lift out the old igniter and harness.
  5. Install — Mount the new igniter in the exact original position, install the new wiring kit, and plug in.
  6. Test — Restore gas and power, run a heat cycle, and confirm the igniter glows and lights the burners promptly.

Signs You Need a Replacement

  • No heat — igniter never glows on a heat call
  • Igniter glows but burners fail to light
  • Visible cracks or breaks in the igniter element
  • Melted, discolored, or corroded igniter connector

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120HTAA0AGAA — OEM 1171306 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120HTAA0AGAA — OEM 1171306 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120HTAA0AGAA — OEM 1171306 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online