Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter with Wiring Kit for RGS101HTCB0AAA — OEM | Ships Today
ICP

ICP Hot Surface Igniter with Wiring Kit for RGS101HTCB0AAA — OEM | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (part 1171306) with matching wiring kit (part 1188370) for the ICP Tempstar Heil RGS101HTCB0AAA furnace provides the heat source that lights the burners at the start of every heating cycle. When the control board energizes the igniter, it glows white-hot to ignite the gas as the valve opens. Hot surface igniters are brittle and degrade with every cycle, making them one of the most frequent furnace failures. The included wiring kit ensures a clean, correct connection and is the right choice when the original harness or connector is brittle, melted, or corroded. A cracked or worn igniter is the classic cause of a furnace that clicks, calls for heat, but never lights.

Specifications

Spec Value
Part Number (Igniter) 1171306
Part Number (Wiring Kit) 1188370
Type Hot Surface Igniter
Brand ICP (Tempstar / Heil)
Includes Igniter + Wiring Harness Kit
Fit OEM Replacement

Compatibility

Designed for the ICP / Tempstar / Heil RGS101HTCB0AAA gas furnace and related ICP-family models using this hot surface ignition system. Verify against your furnace parts diagram before installing.

Installation Guide

  1. Safety First — Disconnect electrical power and shut off gas. Verify zero voltage with a multimeter before working in the burner area.
  2. Access — Remove the furnace service panel to reach the igniter at the burner assembly.
  3. Document — Photograph the igniter position, bracket, and wiring routing before disconnecting.
  4. Remove — Unplug the igniter connector, remove the mounting screw, and carefully withdraw the old igniter without touching the element. Replace the harness with the wiring kit if needed.
  5. Install — Mount the new igniter handling it only by its ceramic base, route and plug in the wiring kit, and confirm proper position over the burner.
  6. Test — Restore gas and power, call for heat, and confirm the igniter glows and the burners light cleanly.

Signs You Need a Replacement

  • Furnace calls for heat but burners never ignite
  • Igniter shows cracks, blistering, or no glow
  • Brittle, melted, or corroded igniter wiring/connector
  • Repeated lockouts after several ignition attempts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS101HTCB0AAA — OEM | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS101HTCB0AAA — OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS101HTCB0AAA — OEM | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online