Overview

This OEM hot surface igniter (part 1171306) with matching wiring kit (part 1188370) replaces the ignition source on the ICP Tempstar Heil RGS091HDBB0AAAA gas furnace. The hot surface igniter glows red-hot when energized on a call for heat, lighting the burners as the gas valve opens. Igniters are the most common gas furnace failure point — the silicon nitride or carbide element is fragile and degrades with every heat cycle until it cracks or no longer reaches ignition temperature, leaving you with no heat. The included wiring kit provides the correct connector and leads so the new igniter mates cleanly to the control board harness without splicing. Handle the igniter element only by its ceramic base; skin oils shorten its life.

Specifications

Spec Value
Part Number (Igniter) 1171306
Part Number (Wiring Kit) 1188370
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Fitment RGS091HDBB0AAAA
Application Gas furnace burner ignition

Compatibility

Designed for the ICP Tempstar Heil RGS091HDBB0AAAA gas furnace and related RGS-series models using the same hot surface ignition system. The wiring kit ensures a correct plug-and-play harness connection.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter bracket position and harness routing before disconnecting.
  4. Remove — Unplug the igniter lead, remove the mounting screw, and carefully withdraw the old igniter without touching the element.
  5. Install — Mount the new igniter by its ceramic base, install the wiring kit connector, and route the harness per your photo.
  6. Test — Restore power, call for heat, and verify the igniter glows and the burners light.

Signs You Need a Replacement

  • No heat — burners never light on a call for heat
  • Visibly cracked, chipped, or broken igniter element
  • Igniter does not glow or glows weakly during the ignition cycle
  • Furnace locks out after several failed ignition attempts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS091HDBB0AAAA — OEM | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS091HDBB0AAAA — OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS091HDBB0AAAA — OEM | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online