Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter with Wiring Harness Kit for RGS102STAA0AAA – OEM | Ships Today
ICP

ICP Hot Surface Igniter with Wiring Harness Kit for RGS102STAA0AAA – OEM | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (part 1171306) with its matching igniter wiring harness kit (part 1188370) is the component that ignites the gas burners in the ICP / Tempstar / Heil RGS102STAA0AAA furnace. On each heat call the control board sends line voltage to the igniter, which glows white-hot to light the burners. Hot surface igniters are brittle and wear out over time — they crack, develop hairline fractures, or simply stop reaching ignition temperature, which is one of the most common causes of no-heat calls. Including the wiring kit ensures a clean, reliable connection and replaces brittle, heat-damaged leads at the same time.

Specifications

Spec Value
Part Numbers 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot surface igniter + wiring harness
Brand ICP / Tempstar / Heil
Function Ignites gas burners on heat call
Includes Igniter element and plug-in wire harness

Compatibility

Engineered for the ICP RGS102STAA0AAA gas furnace and related ICP-family (Tempstar, Heil, Comfortmaker) models using this igniter and harness. Match the igniter mounting bracket and connector style to your existing part before ordering.

Installation Guide

  1. Safety First – Turn off gas and disconnect power; verify zero voltage with a multimeter.
  2. Access – Remove the furnace burner compartment panel.
  3. Document – Photograph the igniter position and harness routing before disconnecting.
  4. Remove – Unplug the harness, remove the igniter mounting screw, and withdraw the old igniter — handle by the bracket only, never the element.
  5. Install – Mount the new igniter (do not touch the glow element with bare fingers), connect the new wiring harness, and verify clearance from the burners.
  6. Test – Restore gas and power, start a heat cycle, and confirm the igniter glows and the burners light.

Signs You Need a Replacement

  • No heat — burners never light despite a thermostat call
  • Igniter visibly cracked, chipped, or not glowing
  • Furnace locks out after several failed ignition attempts
  • Brittle, melted, or chafed igniter wiring

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS102STAA0AAA – OEM | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS102STAA0AAA – OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS102STAA0AAA – OEM | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online