This OEM hot surface igniter (part number 1176919) and matching mounting bracket (part number 1184324) replace the ignition assembly on the ICP/Tempstar/Heil WFAR060B048B1 gas furnace. On each call for heat, the control board sends line voltage to the igniter, which glows white-hot to light the burners. Hot surface igniters are the most common furnace failure point — the brittle element cracks from thermal cycling and age. Symptoms include the furnace running its ignition sequence but never lighting, or short-cycling on ignition lockout. This kit includes the correct bracket so the new igniter sits at the precise factory position relative to the burner.

Specifications

Spec Value
Igniter Part Number 1176919
Bracket Part Number 1184324
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Voltage 120 VAC
Fit OEM direct replacement

Compatibility

Designed for the ICP/Tempstar/Heil WFAR060B048B1 gas furnace and related ICP-family models using this hot surface igniter and bracket. Handle the element by its ceramic base only — skin oils shorten its life.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter wiring connector and bracket position before disconnecting.
  4. Remove — Unplug the igniter lead, remove the bracket screw, and withdraw the old igniter and bracket without touching the element.
  5. Install — Mount the new bracket and igniter, set the element at the factory gap to the burner, and reconnect the lead.
  6. Test — Restore power, start a heat cycle, and confirm the igniter glows and the burners light cleanly.

Signs You Need a Replacement

  • Furnace runs the ignition sequence but burners never light
  • Igniter shows no glow during the heat call
  • Visibly cracked, chipped, or blistered element
  • Repeated ignition-lockout fault codes from the control board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP WFAR060B048B1 — Furnace Ignitor Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP WFAR060B048B1 — Furnace Ignitor Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP WFAR060B048B1 — Furnace Ignitor Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.