Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter & Wiring Kit for RGS150LTAA0AGAA — OEM Furnace Ignitor | Ships Today
ICP

ICP Hot Surface Igniter & Wiring Kit for RGS150LTAA0AGAA — OEM Furnace Ignitor | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter kit fits the ICP Tempstar Heil RGS150LTAA0AGAA gas furnace and includes the genuine ignitor (part 1171306) and the matching wiring harness kit (part 1188370). The hot surface igniter is the element that electrically heats to a glowing temperature to ignite the gas at the burners on each call for heat. Because it is a brittle element cycled to high temperature thousands of times, it eventually cracks or develops hot spots and stops glowing — the most common cause of no-heat furnace calls. The included wiring kit ensures a clean, correctly terminated connection to the control board. Installing this OEM kit restores reliable, fast ignition.

Specifications

Spec Value
Part Number 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Includes Igniter element + wiring harness kit
Application Gas furnace burner ignition
Fits Model RGS150LTAA0AGAA

Compatibility

Designed for the ICP Tempstar Heil RGS150LTAA0AGAA furnace and related RGS-series gas furnaces that use this hot surface igniter and connector. Match the igniter mounting tab and connector style before ordering.

Installation Guide

  1. Safety First — Disconnect electrical power and verify zero voltage with a multimeter; let the igniter area cool fully.
  2. Access — Remove the burner/service panel to reach the igniter at the burner assembly.
  3. Document — Photograph the igniter position and harness routing before disconnecting.
  4. Remove — Unplug the harness and unscrew the cracked igniter; handle only by the ceramic base, never the element.
  5. Install — Mount the new igniter (do not touch the element with bare fingers) and connect the new wiring kit to the control board.
  6. Test — Restore power, call for heat, and confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • No heat — igniter does not glow on a call for heat
  • Visible cracks or hot spots on the igniter element
  • Furnace locks out after several failed ignition attempts
  • Delayed ignition or intermittent burner lighting

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS150LTAA0AGAA — OEM Furnace Ignitor | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS150LTAA0AGAA — OEM Furnace Ignitor | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS150LTAA0AGAA — OEM Furnace Ignitor | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online