Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter & Wiring Kit for RGS150LEBA0AAAA — OEM Ignitor | Ships Today
ICP

ICP Hot Surface Igniter & Wiring Kit for RGS150LEBA0AAAA — OEM Ignitor | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter kit for the ICP RGS150LEBA0AAAA includes the igniter (part 1171306) and its dedicated wiring harness kit (part 1188370). On a call for heat, the control board energizes the igniter; it glows red-hot and lights the burner gas, then the flame sensor confirms a flame. Hot surface igniters are brittle and degrade with every cycle — the silicon carbide or nitride element develops micro-cracks until it can no longer reach ignition temperature. Bundling the wiring kit ensures a clean, corrosion-free connection, since brittle or chafed igniter leads are a frequent cause of intermittent no-heat calls. Typical symptoms include no ignition, a furnace that clicks but never lights, and lockout after several failed ignition attempts.

Specifications

Spec Value
Part Numbers 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot Surface Igniter
Brand ICP (Tempstar / Heil)
Includes Igniter + Wiring Harness Kit
Application Furnace Burner Ignition
Fitment OEM

Compatibility

Built for the ICP / Tempstar / Heil RGS150LEBA0AAAA package gas unit and related models using the same hot surface ignition system. Confirm the igniter mounting and connector match your existing part.

Installation Guide

  1. Safety First — Shut off gas, disconnect power, and verify zero voltage with a multimeter.
  2. Access — Remove the burner/service panel to reach the igniter at the burner assembly.
  3. Document — Photograph the igniter position and harness routing before disconnecting.
  4. Remove — Unplug the wiring connector and unscrew the brittle old igniter — handle by the base, never the element.
  5. Install — Mount the new igniter without touching the element, then connect the new wiring kit and route it clear of hot surfaces.
  6. Test — Restore gas and power, run a heat call, and verify the igniter glows and lights the burners promptly.

Signs You Need a Replacement

  • No ignition — burners never light on a heat call
  • Igniter does not glow or glows weakly
  • Visible cracks or breaks in the igniter element
  • Furnace locks out after repeated failed ignition attempts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS150LEBA0AAAA — OEM Ignitor | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS150LEBA0AAAA — OEM Ignitor | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS150LEBA0AAAA — OEM Ignitor | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online