Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter & Wiring Kit for RGS120SFAB0AAA - OEM Ignitor | Ships Today
ICP

ICP Hot Surface Igniter & Wiring Kit for RGS120SFAB0AAA - OEM Ignitor | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM kit pairs the hot surface igniter (Part No. 1171306) with its matching igniter wiring kit (Part No. 1188370) for the ICP / Tempstar / Heil RGS120SFAB0AAA gas furnace. The hot surface igniter is the component that glows red-hot when the furnace calls for heat, lighting the gas at the burners. It is one of the most frequently replaced furnace parts because the igniter element is brittle and degrades with every heat cycle until it eventually cracks or fails to reach ignition temperature. Including the fresh wiring harness ensures the connector and leads are not the cause of intermittent or no-ignition faults. When this part fails you typically get a furnace that cycles the inducer and gas valve but never lights, ending in a lockout.

Specifications

Spec Value
Igniter Part Number 1171306
Wiring Kit Part Number 1188370
Type Hot Surface Igniter with Wiring Harness
Brand ICP / Tempstar / Heil
Fit OEM Replacement
Application Gas Furnace Ignition

Compatibility

Designed for the ICP / Tempstar / Heil RGS120SFAB0AAA and other ICP-family gas furnaces using this hot surface igniter and connector. Confirm OEM part numbers 1171306 and 1188370 against your current igniter and harness before ordering.

Installation Guide

  1. Safety First - Disconnect electrical power and shut off the gas, then verify zero voltage with a multimeter before reaching into the burner area.
  2. Access - Remove the burner compartment door to expose the igniter at the burner.
  3. Document - Photograph the igniter position, mounting screw, and harness routing before disconnecting.
  4. Remove - Unplug the igniter harness, remove the mounting screw, and lift out the old igniter. Handle only by the ceramic base, never the fragile element.
  5. Install - Mount the new igniter so the element sits correctly in the burner flame path, then connect the new wiring kit per your photo.
  6. Test - Restore gas and power, start a heat cycle, and confirm the igniter glows and lights the burners promptly.

Signs You Need a Replacement

  • Furnace runs the inducer but never ignites, then locks out
  • Visible cracks or a chipped, eroded igniter element
  • Igniter does not glow or glows weakly/unevenly
  • Intermittent no-heat calls caused by a damaged igniter connector

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120SFAB0AAA - OEM Ignitor | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120SFAB0AAA - OEM Ignitor | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120SFAB0AAA - OEM Ignitor | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.