Overview

This OEM ignition kit pairs the hot surface igniter, ICP part 1171306, with its dedicated wiring kit, part 1188370, for the Tempstar / Heil RGS120LTBA0AAA gas furnace. The hot surface igniter (HSI) is the element that glows white-hot on a call for heat to ignite the burner gas — it replaces older standing-pilot and spark systems. The included wiring kit provides the correct OEM connector and lead harness so the igniter mates cleanly to the furnace control without splicing. HSIs are fragile and degrade with every heating cycle; the element eventually cracks, develops hairline fractures, or simply burns out. A failed igniter is the single most common reason a furnace inducer runs but the burners never light.

Specifications

Spec Value
Igniter Part Number 1171306
Wiring Kit Part Number 1188370
Type Hot Surface Igniter
Brand ICP (Tempstar / Heil)
Includes Igniter + OEM wiring harness/connector

Compatibility

Direct-fit replacement for the ICP / Tempstar / Heil RGS120LTBA0AAA and related Carrier-family furnaces using igniter 1171306. The 1188370 wiring kit ensures a plug-and-play connection to the furnace control board.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter; let the igniter cool fully before handling.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter mounting and wire routing before removal.
  4. Remove — Unplug the igniter harness and unscrew the old igniter, handling it only by the ceramic base — never touch the element.
  5. Install — Mount the new igniter (handle by the base only), then connect the new wiring kit to the control board.
  6. Test — Restore power, call for heat, and watch the igniter glow and the burners light within the ignition sequence.

Signs You Need a Replacement

  • Inducer runs but burners never ignite
  • Igniter does not glow on a heat call
  • Visible cracks or hairline fractures in the element
  • Furnace lockout after several failed ignition attempts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120LTBA0AAA — OEM | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120LTBA0AAA — OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120LTBA0AAA — OEM | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.