Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter & Wiring Kit for RGS120HFBA0AGAA — OEM | Ships Today
ICP

ICP Hot Surface Igniter & Wiring Kit for RGS120HFBA0AGAA — OEM | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (part 1171306) and matching igniter wiring kit (part 1188370) replace the ignition source on the ICP/Heil/Tempstar RGS120HFBA0AGAA gas furnace. The hot surface igniter glows red-hot when energized to light the burners at the start of each heat cycle; the wiring kit provides the correct connector and harness so the igniter ties cleanly into the control board. Igniters are brittle and degrade with every cycle, eventually cracking or losing the ability to reach ignition temperature. Common failure symptoms include no heat with the blower running, a furnace that locks out after several ignition attempts, or an igniter that no longer glows.

Specifications

Spec Value
Part Numbers 1171306 (igniter), 1188370 (wiring kit)
Type Hot surface igniter
Brand ICP / Heil / Tempstar (genuine OEM)
Includes Igniter + wiring harness/connector kit
Function Burner ignition

Compatibility

Designed for the ICP/Heil/Tempstar/Comfortmaker RGS120HFBA0AGAA gas furnace and related RGS-series models using a hot surface ignition system. Match the igniter mounting and connector to your old unit before installing.

Installation Guide

  1. Safety First — Shut off gas and disconnect power, then verify zero voltage with a multimeter. Handle the igniter only by its ceramic base — skin oils and finger pressure crack the element.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter position and wiring routing.
  4. Remove — Disconnect the igniter harness, unscrew the igniter bracket, and lift out the old element.
  5. Install — Mount the new igniter without touching the element, then connect the new wiring kit to the control board per your photo.
  6. Test — Restore gas and power, call for heat, and confirm the igniter glows and the burners light.

Signs You Need a Replacement

  • No heat although the blower and call for heat are present
  • Furnace locks out after repeated ignition attempts
  • Igniter does not glow when energized
  • Visible crack or break in the ceramic element

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120HFBA0AGAA — OEM | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120HFBA0AGAA — OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120HFBA0AGAA — OEM | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online