Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter & Wiring Kit for RGS102HTCB0AAA — OEM Ignitor | Ships Today
ICP

ICP Hot Surface Igniter & Wiring Kit for RGS102HTCB0AAA — OEM Ignitor | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (part 1171306) and matching igniter wiring kit (part 1188370) restore reliable ignition on the ICP Tempstar Heil RGS102HTCB0AAA gas furnace. On a heat call, the control board energizes the igniter, which glows white-hot to light the burners. The included wiring kit replaces the brittle, heat-aged igniter harness and connector so you get a complete, clean repair. Hot surface igniters are fragile and degrade over thousands of cycles. Failure symptoms include no ignition with the blower running, a furnace that locks out after several ignition attempts, a visibly cracked or no-longer-glowing igniter, and short-cycling on heat.

Specifications

Spec Value
Part Numbers 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot Surface Igniter with Wiring Kit
Brand ICP / Tempstar / Heil
Application Gas Furnace Burner Ignition
Fitment OEM Replacement

Compatibility

Built for the ICP Tempstar Heil RGS102HTCB0AAA gas furnace and related ICP-family furnaces using this hot surface igniter and harness. Match the igniter mounting and connector to your original before installing — these elements are brittle and break easily if forced.

Installation Guide

  1. Safety First — Turn off gas and power, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment service panel.
  3. Document — Photograph the igniter position and harness routing before disconnecting.
  4. Remove — Unplug the old igniter connector, remove its mounting screw, and lift the igniter out without touching the new element with bare fingers.
  5. Install — Mount the new igniter, route and connect the new wiring kit, and seat the connector firmly per your photo.
  6. Test — Restore gas and power, then run a heat cycle and confirm the igniter glows and lights the burners promptly.

Signs You Need a Replacement

  • No ignition even though the inducer and blower run
  • Furnace locks out after repeated ignition attempts
  • Igniter is cracked or no longer glows
  • Short-cycling or delayed ignition on heat calls

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS102HTCB0AAA — OEM Ignitor | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS102HTCB0AAA — OEM Ignitor | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS102HTCB0AAA — OEM Ignitor | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online