Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter & Wiring Kit for RGS102HTAA0AAA — OEM | Ships Today
ICP

ICP Hot Surface Igniter & Wiring Kit for RGS102HTAA0AAA — OEM | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (part 1171306) with matching wiring kit (part 1188370) for the ICP / Heil / Tempstar RGS102HTAA0AAA gas furnace provides the spark-free ignition source that lights the burners on every heat call. When the control board sends power to the igniter, its silicon-carbide or nitride element glows white-hot and ignites the gas as the valve opens. Igniters are a top wear item — the brittle element cracks from thermal cycling, vibration, and oil or dust contamination, and the supply leads fatigue at the connector. Including the wiring kit ensures a clean, factory-correct electrical connection and avoids re-using brittle, heat-damaged leads. A failed igniter is the most common reason a furnace ignites no heat despite the inducer and blower running.

Specifications

Spec Value
Part Number 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot Surface Igniter
Brand ICP (Heil / Tempstar / Comfortmaker)
Includes Igniter + Wiring Harness Kit
Fits Model RGS102HTAA0AAA
Application Gas Furnace Burner Ignition
Fit OEM

Compatibility

Built for the ICP-family RGS102HTAA0AAA gas furnace and related Heil, Tempstar, and Comfortmaker furnaces using the same hot surface igniter and connector. Match the igniter shape and mounting bracket to your original before ordering.

Installation Guide

  1. Safety First — Disconnect furnace power and verify zero voltage with a multimeter; allow the igniter to cool fully.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter position, bracket, and wiring routing before removal.
  4. Remove — Unplug the igniter lead, remove the mounting screw, and lift the fragile igniter straight out without touching the element.
  5. Install — Mount the new igniter handling it only by the ceramic base, install the new wiring kit, and route the harness clear of hot surfaces.
  6. Test — Restore power and confirm the igniter glows and burners light within the normal ignition sequence.

Signs You Need a Replacement

  • Furnace inducer and blower run but burners never light
  • Visible crack or break in the igniter element
  • No glow during the ignition sequence
  • Repeated ignition lockouts or short-cycling on heat

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS102HTAA0AAA — OEM | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS102HTAA0AAA — OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS102HTAA0AAA — OEM | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online