Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter & Wiring Kit for RGS102HRAB0AAA — OEM Ignitor | Ships Today
ICP

ICP Hot Surface Igniter & Wiring Kit for RGS102HRAB0AAA — OEM Ignitor | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM kit pairs the hot surface igniter (part number 1171306) with its matching wiring kit (part number 1188370) for the ICP / Tempstar / Heil RGS102HRAB0AAA gas furnace. On each heat call the control board energizes the igniter, which glows red-hot to light the burners; the included wiring harness provides the correct plug and leads for a clean, no-splice connection. Hot surface igniters are the most common no-heat failure in modern furnaces — the silicon nitride or carbide element is brittle and degrades with every cycle until it cracks, develops hairline fractures, or simply fails to reach ignition temperature. Symptoms include the inducer running and gas valve clicking with no flame, repeated ignition lockouts, or a furnace that short-cycles on failed light-off. Replacing the igniter and harness together avoids reusing a heat-fatigued connector.

Specifications

Spec Value
Part Numbers 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot Surface Igniter + Harness
Brand ICP / Tempstar / Heil
Function Burner ignition
Includes Igniter element and wiring kit
Fits Model RGS102HRAB0AAA

Compatibility

Designed for the ICP-family RGS102HRAB0AAA and related RGS102-series furnaces that use this hot surface igniter. Confirm the igniter mounting and connector style against your existing part before ordering. Handle the ceramic element only by its base — skin oils and any contact can crack the brittle tip.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter; allow the igniter to cool fully.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter mounting and harness routing before disconnecting.
  4. Remove — Unplug the harness, remove the igniter mounting screw, and lift the old igniter out without touching the element.
  5. Install — Mount the new igniter by its base, route and connect the new wiring kit, and seat the connector fully.
  6. Test — Restore power, start a heat cycle, and confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • Inducer runs and gas valve clicks but burners never light
  • Visible cracks or breaks in the igniter element
  • Repeated ignition lockouts or short-cycling on light-off
  • Igniter glows weakly or not at all

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS102HRAB0AAA — OEM Ignitor | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS102HRAB0AAA — OEM Ignitor | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS102HRAB0AAA — OEM Ignitor | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online