Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter & Wiring Kit for RGS101LSCB0AAA — OEM Ignitor | Ships Today
ICP

ICP Hot Surface Igniter & Wiring Kit for RGS101LSCB0AAA — OEM Ignitor | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine ICP hot surface igniter (part 1171306) plus matching igniter wiring kit (part 1188370) provides the ignition source for the ICP / Tempstar / Heil RGS101LSCB0AAA gas furnace. On a call for heat, the control board energizes the igniter, which glows red-hot to ignite gas at the burners. Hot surface igniters are fragile and degrade with every heating cycle until they crack or no longer reach ignition temperature — the most common reason a furnace blows cold air or fails to light. The included wiring kit ensures a clean, corrosion-free harness connection. Handle the igniter element by its ceramic base only; oils from skin shorten its life.

Specifications

Spec Value
Part Number 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot Surface Igniter with Wiring Harness
Brand ICP / Tempstar / Heil
Function Burner ignition
Fit OEM Genuine Replacement
Application Gas furnace ignition

Compatibility

Built for the ICP / Tempstar / Heil RGS101LSCB0AAA gas furnace and related ICP-family units using this hot surface igniter and connector. Match the igniter mounting and plug style to your existing part before installing.

Installation Guide

  1. Safety First — Shut off gas, disconnect power at the breaker, and verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter position and wiring routing before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and lift out the old igniter without touching the element.
  5. Install — Mount the new igniter by its ceramic base, route and connect the new wiring kit per your photo.
  6. Test — Restore gas and power, call for heat, and confirm the igniter glows and burners light.

Signs You Need a Replacement

  • Furnace blows cold air or fails to ignite
  • Igniter never glows or glows weakly
  • Visible cracks or breaks in the igniter element
  • Repeated lockouts after several ignition attempts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS101LSCB0AAA — OEM Ignitor | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS101LSCB0AAA — OEM Ignitor | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS101LSCB0AAA — OEM Ignitor | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online