Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter & Wiring Kit for RGS101HDBB0AAAA — OEM | Ships Today
ICP

ICP Hot Surface Igniter & Wiring Kit for RGS101HDBB0AAAA — OEM | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (part 1171306) with matching igniter wiring kit (part 1188370) is the factory ignition component for the ICP Tempstar Heil RGS101HDBB0AAAA gas furnace. On a call for heat, the control board energizes the igniter, which glows red-hot and ignites the gas at the burners. The included wiring kit supplies the correct connector and leads so the igniter mates cleanly to the harness. Hot surface igniters are fragile and degrade over thousands of heating cycles — the element thins, cracks, and eventually fails to reach ignition temperature, causing no-heat calls, delayed ignition, or a furnace that locks out after several failed ignition attempts. Replacing the igniter together with its wiring kit restores fast, reliable ignition.

Specifications

Spec Value
Igniter Part Number 1171306 (IGNITOR)
Wiring Kit Part Number 1188370 (WIRING KIT IGNITER)
Type Hot surface igniter
Brand ICP / Tempstar / Heil
Application Gas furnace burner ignition
Fitment OEM, factory-correct

Compatibility

Fits the ICP Tempstar Heil RGS101HDBB0AAAA and related furnaces using this hot surface igniter. Match the element style and connector to your original before installing.

Installation Guide

  1. Safety First — Turn off the furnace power and gas, then verify zero voltage with a multimeter. Let the igniter area cool completely.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter mounting position and harness connection before disconnecting.
  4. Remove — Unplug the igniter lead, remove the mounting screw, and lift out the old igniter. Handle the new element only by its ceramic base — never touch the gray element.
  5. Install — Mount the new igniter in the same position, connect the wiring kit lead to the harness, and confirm the element sits correctly over the burner.
  6. Test — Restore gas and power, start a heat cycle, and verify the igniter glows and lights the burners promptly.

Signs You Need a Replacement

  • No heat — igniter does not glow on a call for heat
  • Cracked, chipped, or visibly worn element
  • Delayed ignition or rough/booming light-off
  • Furnace locks out after repeated failed ignition attempts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS101HDBB0AAAA — OEM | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS101HDBB0AAAA — OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS101HDBB0AAAA — OEM | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online