Overview

This OEM kit pairs the hot surface igniter (Part No. 1171306) with its matching wiring kit (Part No. 1188370) for the ICP, Tempstar, and Heil RGS091SFCA0AAA gas furnace. On a call for heat, the control board sends line voltage to the igniter, which glows red-hot to ignite the gas at the burners. The hot surface igniter is one of the most common furnace failure points — the element is fragile and degrades with every heat cycle until it eventually cracks and stops glowing. The included wiring kit provides the correct factory harness/connector so you get a clean, complete repair rather than splicing a brittle old lead. Symptoms of a failed igniter include no ignition, repeated lockouts, or a unit that tries to light then shuts down.

Specifications

Spec Value
Part Numbers 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot Surface Igniter + Wiring Harness
Brand ICP / Tempstar / Heil
Operating Voltage 120 VAC
Function Gas burner ignition
Fitment OEM

Compatibility

Designed for the ICP/Tempstar/Heil RGS091SFCA0AAA and other RGS-series gas furnaces using the 1171306 igniter and 1188370 wiring kit. Match the part numbers and connector style to your unit before ordering.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage; never touch the igniter element with bare fingers.
  2. Access — Remove the burner compartment door.
  3. Document — Photograph the igniter position and wiring connector before removal.
  4. Remove — Unplug the harness, remove the igniter mounting screw, and lift out the old igniter without touching the element.
  5. Install — Mount the new igniter (handle by the base only), then connect the new wiring kit to the control board.
  6. Test — Restore power, start a heat cycle, and confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • Igniter does not glow on a call for heat.
  • Furnace locks out or short-cycles without igniting.
  • Visible crack, blister, or burn-through on the element.
  • Repeated failed ignition attempts before shutdown.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS091SFCA0AAA — OEM Ignitor | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS091SFCA0AAA — OEM Ignitor | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS091SFCA0AAA — OEM Ignitor | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.