Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter & Wiring Kit for RGS091HTCB0AAA — OEM Ignitor | Ships Today
ICP

ICP Hot Surface Igniter & Wiring Kit for RGS091HTCB0AAA — OEM Ignitor | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM kit pairs the genuine ICP hot surface igniter (part 1171306) with its matching wiring kit (part 1188370) for the RGS091HTCB0AAA gas furnace. The hot surface igniter is the component that glows red-hot when energized and ignites the gas at the burners on each heat call. Because the igniter element is heated to extreme temperatures thousands of times per season, it is one of the most common furnace wear items — the brittle silicon-carbide or nitride element eventually cracks, develops hairline fractures, or fails open, leaving the furnace unable to light. The included wiring kit replaces the original igniter harness and connector, eliminating the brittle, heat-aged wiring that often fails alongside the element. Together they restore reliable, on-demand ignition.

Specifications

Spec Value
Part Number 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot Surface Igniter with Wiring Kit
Brand ICP / Heil / Tempstar / Comfortmaker
Element Hot surface ignition element
Fit Genuine OEM
Application Gas furnace burner ignition

Compatibility

Designed for the ICP/Tempstar/Heil RGS091HTCB0AAA gas furnace and ICP-family units using the same hot surface ignition system. Match the igniter mounting block and connector to your existing part before installing.

Installation Guide

  1. Safety First — Shut off gas and electrical power, then verify zero voltage with a multimeter. Let the burner area cool fully.
  2. Access — Remove the furnace burner-compartment service panel.
  3. Document — Photograph the igniter position and harness routing before disconnecting.
  4. Remove — Unplug the igniter connector, unscrew the mounting bracket, and lift out the old igniter — handle only by the ceramic base, never the element.
  5. Install — Mount the new igniter without touching the element, install the new wiring kit, and route the harness clear of hot surfaces.
  6. Test — Restore gas and power, call for heat, and confirm the igniter glows and lights the burners promptly.

Signs You Need a Replacement

  • Furnace blower runs but burners never ignite
  • Igniter does not glow or only glows dimly on a heat call
  • Visible cracks or breaks in the igniter element
  • Brittle, melted, or chafed igniter wiring and connector

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS091HTCB0AAA — OEM Ignitor | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS091HTCB0AAA — OEM Ignitor | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS091HTCB0AAA — OEM Ignitor | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online