Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter & Wiring Kit for RGS091HSBB0AAAA — OEM 1171306 | Ships Today
ICP

ICP Hot Surface Igniter & Wiring Kit for RGS091HSBB0AAAA — OEM 1171306 | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter kit for the ICP Tempstar/Heil RGS091HSBB0AAAA includes the igniter (part 1171306) and a matching igniter wiring kit (part 1188370). On a heat call, the control board sends voltage to the igniter, which glows red-hot to ignite the burners. Hot surface igniters are fragile and degrade with every cycle, eventually cracking or failing to reach ignition temperature. The result is no heat, repeated ignition lockouts, or a furnace that smells like gas but won't light. Including fresh wiring ensures the connector and leads aren't the hidden cause of an intermittent ignition fault.

Specifications

Spec Value
Part Numbers 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot Surface Igniter with Wiring Harness
Brand ICP (Tempstar / Heil)
Operating Voltage 120V
Function Burner Ignition
Fitment OEM Replacement
Model RGS091HSBB0AAAA

Compatibility

Direct OEM fit for the ICP Tempstar Heil RGS091HSBB0AAAA gas furnace. The included wiring kit matches the OEM connector for this platform. ICP-family furnaces (Tempstar, Heil, Comfortmaker) often share igniter mounting — verify part numbers 1171306 and 1188370 and the igniter mounting style before installing.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter before working in the burner compartment.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter position and wiring connector before disconnecting.
  4. Remove — Unplug the igniter harness and remove the mounting screw(s); handle the old igniter by its ceramic base only.
  5. Install — Mount the new igniter without touching the hot surface element, then connect the new wiring kit per your photo.
  6. Test — Restore power, start a heat call, and confirm the igniter glows and burners light within the normal sequence.

Signs You Need a Replacement

  • Furnace won't ignite or locks out after several attempts
  • Igniter shows visible cracks or no longer glows
  • Gas smell at startup with no ignition
  • Intermittent no-heat calls or a frayed igniter connector

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS091HSBB0AAAA — OEM 1171306 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS091HSBB0AAAA — OEM 1171306 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS091HSBB0AAAA — OEM 1171306 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online