Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter & Wiring Kit for RGS091HRAB0AAAA — OEM | Ships Today
ICP

ICP Hot Surface Igniter & Wiring Kit for RGS091HRAB0AAAA — OEM | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM hot surface igniter (part #1171306) with its matching igniter wiring kit (part #1188370) for the ICP / Heil / Tempstar RGS091HRAB0AAAA gas furnace. The hot surface igniter glows to high temperature when the control board calls for heat, lighting the burners on each cycle. Because the igniter is a brittle silicon-carbide (or nitride) element, it is one of the most common no-heat failures — it cracks from age, thermal stress, or handling, or simply burns out after thousands of cycles. The included wiring kit provides the correct connector and harness so you get a complete, plug-and-play replacement rather than splicing into the old leads.

Specifications

Spec Value
Part Number 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot Surface Igniter
Brand ICP / Heil / Tempstar (OEM)
Includes Igniter + connector/wiring harness
Application Gas furnace burner ignition
Fitment RGS091HRAB0AAAA

Compatibility

Designed for the ICP / Heil / Tempstar / Comfortmaker RGS091HRAB0AAAA gas furnace and related RGS-series furnaces using this hot surface ignition system. Handle the igniter element only by its ceramic base — never touch the glow area.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment service panel.
  3. Document — Photograph the igniter position, bracket, and wiring connector before removing.
  4. Remove — Unplug the igniter harness, remove the mounting screw(s), and carefully lift out the old element.
  5. Install — Mount the new igniter (handling only the ceramic base), connect the new wiring kit, and route the harness clear of hot surfaces.
  6. Test — Restore power, start a heat cycle, and confirm the igniter glows bright and the burners light promptly.

Signs You Need a Replacement

  • No heat — furnace blower runs but burners never light
  • Igniter does not glow or glows weakly
  • Visible cracks or breaks in the igniter element
  • Furnace locks out after several failed ignition attempts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS091HRAB0AAAA — OEM | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS091HRAB0AAAA — OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS091HRAB0AAAA — OEM | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online