Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter (Sparker) for RGS180SRAA0AAAA — 24V | Ships Today
ICP

ICP Hot Surface Igniter (Sparker) for RGS180SRAA0AAAA — 24V | Ships Today

SKU: 1184216 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM spark igniter (part #1184216) ignites the burner gas in your ICP, Tempstar, and Heil RGS180SRAA0AAAA gas furnace. On each heat call, the ignition control sends 24V to the igniter, which generates a high-voltage spark at the burner to light the gas. A worn or cracked igniter is a leading cause of intermittent or failed ignition. Because the igniter sits directly in the harsh, high-temperature burner environment, the electrode and ceramic insulator degrade over time. When it fails, the furnace blower may run while no heat is produced, or the system locks out after several failed ignition attempts.

Specifications

Spec Value
Part Number 1184216
Type Spark Igniter / Ignitor
Brand ICP / Tempstar / Heil
Control Voltage 24V
Application Gas Furnace Burner Ignition

Compatibility

Designed as the factory replacement for the ICP/Tempstar/Heil RGS180SRAA0AAAA gas furnace. This igniter is shared across multiple ICP-family furnace models using the same direct-spark ignition system. Confirm the mounting position and electrode geometry match the unit you are servicing.

Installation Guide

  1. Safety First — Shut off gas and disconnect power; verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment service panel.
  3. Document — Photograph the igniter position and wire routing before disconnecting.
  4. Remove — Disconnect the igniter lead and remove the mounting screw(s); handle the old igniter by its base only.
  5. Install — Mount the new igniter without touching the ceramic, set the correct gap to the burner, and reconnect the lead.
  6. Test — Restore gas and power, then watch a full ignition cycle for a clean spark and steady flame.

Signs You Need a Replacement

  • Furnace blower runs but produces no heat
  • System locks out after repeated failed ignition attempts
  • Visible cracks in the ceramic insulator or eroded electrode
  • Weak, intermittent, or no spark at the burner

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS180SRAA0AAAA — 24V | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS180SRAA0AAAA — 24V | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS180SRAA0AAAA — 24V | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart