Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Sparker for RGS180SEEA0AAAA — Direct Spark Ignitor | Ships Today
ICP

ICP Hot Surface Igniter Sparker for RGS180SEEA0AAAA — Direct Spark Ignitor | Ships Today

SKU: 1184216 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM spark ignitor (part number 1184216) is the ignition component for the ICP Tempstar Heil RGS180SEEA0AAAA gas furnace. The igniter generates the high-voltage spark that lights the burners on each call for heat. When an igniter fails or weakens, the furnace will fail to light, lock out after several ignition attempts, or short-cycle on startup. A clean, properly gapped igniter is essential for reliable, safe furnace operation.

Specifications

Spec Value
Part Number 1184216
Type Spark Ignitor
Brand ICP / Tempstar / Heil
Fitment OEM Replacement
Application Gas Furnace Ignition

Compatibility

Designed as a direct OEM fit for the ICP Tempstar Heil RGS180SEEA0AAAA gas furnace and shared-platform RGS180 series units. Always confirm your model and serial number before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, shut off the gas, and verify zero voltage with a multimeter.
  2. Access — Remove the furnace front service panel.
  3. Document — Photograph the igniter wiring and bracket position before disconnecting.
  4. Remove — Disconnect the igniter lead, remove the mounting screw, and lift the old igniter from the burner assembly.
  5. Install — Mount the new igniter, set the correct spark gap, and reconnect the lead per your photo.
  6. Test — Restore gas and power, then verify clean ignition through a full heat cycle.

Signs You Need a Replacement

  • Furnace fails to light or locks out after repeated ignition attempts
  • Weak, intermittent, or no spark at the burners
  • Cracked, eroded, or carbon-fouled igniter tip
  • Short-cycling on startup with no heat output

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS180SEEA0AAAA — Direct Spark Ignitor | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS180SEEA0AAAA — Direct Spark Ignitor | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS180SEEA0AAAA — Direct Spark Ignitor | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online