Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit with Wiring Harness for RGS150SECB0AAAA — OEM Fit | Ships Today
ICP

ICP Hot Surface Igniter Kit with Wiring Harness for RGS150SECB0AAAA — OEM Fit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM ignition kit includes the hot surface igniter (part 1171306) and the matching igniter wiring kit (part 1188370) for your ICP Tempstar/Heil RGS150SECB0AAAA gas unit. On a heating call, the control board energizes the hot surface igniter, which glows red-hot to ignite the gas as it leaves the burner. The included wiring kit replaces the high-temperature igniter leads and connector that degrade over time from repeated heat cycling. Hot surface igniters are brittle and one of the most common no-heat failures — they crack from thermal stress, age out, or develop high resistance. Replacing the igniter together with fresh wiring restores reliable ignition and eliminates intermittent connector faults.

Specifications

Spec Value
Part Numbers 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot surface igniter with wiring harness
Brand ICP (Tempstar / Heil)
Function Gas burner ignition
Fit OEM direct replacement
Application Gas furnace / gas-electric package unit

Compatibility

Engineered for the ICP/Tempstar/Heil RGS150SECB0AAAA and related RGS-series gas units that use this hot surface igniter and wiring kit. Confirm the igniter mounting and connector match your existing assembly before installing.

Installation Guide

  1. Safety First — Shut off the gas supply, disconnect power, and verify zero voltage with a multimeter.
  2. Access — Remove the burner/service compartment panel.
  3. Document — Photograph the igniter position and wiring routing before disconnecting.
  4. Remove — Unplug the old igniter harness and unfasten the cracked or failed igniter (handle by the ceramic base only — never touch the element).
  5. Install — Mount the new igniter at the correct burner position, connect the new wiring kit, and route leads away from heat.
  6. Test — Restore gas and power, start a heat cycle, and confirm the igniter glows and the burners light reliably.

Signs You Need a Replacement

  • No heat / furnace fails to ignite
  • Igniter does not glow or glows weakly
  • Visibly cracked or broken igniter element
  • Intermittent ignition or repeated lockouts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS150SECB0AAAA — OEM Fit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS150SECB0AAAA — OEM Fit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS150SECB0AAAA — OEM Fit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera