Overview

This OEM hot surface igniter kit for the ICP/Tempstar/Heil RGS120SRCB0AAA gas furnace includes the igniter element (PN 1171306) and the matching igniter wiring kit/harness (PN 1188370). On each call for heat, the control board sends line voltage to the igniter, which glows red-hot to light the burners before the gas valve opens. Hot surface igniters are brittle silicon-nitride or silicon-carbide elements that degrade with every heating cycle and eventually crack or lose conductivity. The included wiring kit lets you replace a brittle or heat-damaged harness and connector at the same time, eliminating a common hidden cause of intermittent no-heat calls. A fresh igniter restores fast, reliable ignition and prevents nuisance lockouts on cold mornings.

Specifications

Spec Value
Part Numbers 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Includes Igniter Element + Wiring Harness
Fit OEM Replacement

Compatibility

Designed for the ICP family RGS120SRCB0AAA gas furnace and related ICP, Tempstar, Heil, and Comfortmaker furnaces using the same hot surface ignition system and connector. Match the igniter mounting and plug to your existing part.

Installation Guide

  1. Safety First — Disconnect electrical power and shut off the gas; verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment door to reach the igniter at the burner assembly.
  3. Document — Photograph the igniter position and harness routing before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and lift out the old igniter without touching the glow element.
  5. Install — Mount the new igniter (handle by the ceramic base only), route and plug in the new wiring kit, and confirm clearance to the burners.
  6. Test — Restore gas and power, start a heat cycle, and verify the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • No heat with the blower running but burners never lighting
  • Igniter does not glow or glows weakly on a heat call
  • Visible cracks or breaks in the igniter element
  • Furnace locks out after several failed ignition attempts

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120SRCB0AAA — OEM Ignitor | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120SRCB0AAA — OEM Ignitor | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120SRCB0AAA — OEM Ignitor | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online