Overview

This OEM kit pairs the hot surface igniter (part #1171306) with its matching igniter wiring harness kit (part #1188370) for the ICP / Tempstar / Heil RGS120LFAB0AGAA gas furnace. On every heat call the control board sends line voltage to the igniter, which glows white-hot to light the burners. Hot surface igniters are brittle silicon-carbide or silicon-nitride elements that crack with age, thermal cycling, or a finger touch — and a hairline crack means no ignition and no heat. Including the wiring kit ensures the connector and leads aren't the weak link after a tough igniter replacement.

Specifications

Spec Value
Igniter Part Number 1171306
Wiring Kit Part Number 1188370
Type Hot surface igniter + wiring harness
Brand ICP / Tempstar / Heil
Application Gas furnace burner ignition
Fit OEM

Compatibility

Designed for the ICP / Tempstar / Heil RGS120LFAB0AGAA gas furnace and related Carrier-family models using this hot surface igniter and connector. Match the igniter's mounting tab and connector to your old unit before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch/breaker and verify zero voltage with a multimeter; never touch the igniter element with bare fingers.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter bracket position and the wiring connector routing.
  4. Remove — Unplug the igniter connector, remove the mounting screw(s), and carefully withdraw the old igniter from the burner.
  5. Install — Mount the new igniter (handling only the ceramic base), install the new wiring harness, and seat the connector fully.
  6. Test — Restore power, start a heat call, and confirm the igniter glows and lights the burners within the ignition trial.

Signs You Need a Replacement

  • No glow on a heat call (visible crack or open element)
  • Furnace locks out after several failed ignition attempts
  • Igniter glows but is dull/weak and fails to light gas
  • Cracked ceramic or a melted/loose igniter connector

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120LFAB0AGAA — OEM Ignitor | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120LFAB0AGAA — OEM Ignitor | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120LFAB0AGAA — OEM Ignitor | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online