Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit with Wiring Harness for RGS101LFAB0AAAA — OEM 1171306 / 1188370 | Ships Today
ICP

ICP Hot Surface Igniter Kit with Wiring Harness for RGS101LFAB0AAAA — OEM 1171306 / 1188370 | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM hot surface igniter (part 1171306) bundled with its matching igniter wiring kit (part 1188370) for the ICP / Tempstar / Heil RGS101LFAB0AAAA gas furnace. On each heat call the control board sends line voltage to the igniter, which glows white-hot to light the burners. Hot surface igniters are brittle and degrade with every thermal cycle — eventually cracking, losing resistance, or simply failing to glow, which leaves the furnace locked out with no heat. This kit pairs a fresh igniter with the correct pre-terminated wiring harness so you restore a clean electrical connection and reliable ignition in one job.

Specifications

Spec Value
Part Number (Igniter) 1171306 — IGNITOR
Part Number (Wiring) 1188370 — WIRING KIT IGNITER
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Includes Igniter element + wiring harness kit
Fits Model RGS101LFAB0AAAA
Fit OEM Genuine Replacement

Compatibility

Engineered for the ICP-built RGS101LFAB0AAAA and shared across many Tempstar, Heil and Comfortmaker RGS-series gas furnaces using the same hot surface igniter and harness. Verify against your model's parts list before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter position and harness routing before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and lift out the old igniter — handle only by the ceramic base, never the element.
  5. Install — Mount the new igniter (do not touch the glow element), connect the new wiring kit, and confirm correct gap and alignment to the burner.
  6. Test — Restore power, start a heat call, and confirm the igniter glows and lights the burners on the first try.

Signs You Need a Replacement

  • Furnace clicks and tries to start but never lights (no glow).
  • Visible crack, chip, or white-spotting on the igniter element.
  • Control board locks out after repeated failed ignition attempts.
  • Igniter reads out-of-range or open resistance on a meter.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS101LFAB0AAAA — OEM 1171306 / 1188370 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS101LFAB0AAAA — OEM 1171306 / 1188370 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS101LFAB0AAAA — OEM 1171306 / 1188370 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online