Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for X8MPN075B12A2 — Silicon Nitride HSI | Ships Today
ICP

ICP Hot Surface Igniter Kit for X8MPN075B12A2 — Silicon Nitride HSI | Ships Today

SKU: 1172533 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (HSI) assembly is the direct-fit ignition component for the ICP / Heil / Tempstar X8MPN075B12A2 75,000 BTU gas furnace. The hot surface igniter (OEM #1172533) glows red-hot to ignite the burners on each call for heat, working in concert with the flame sensor (OEM #1172543) that confirms a stable flame and the Honeywell VR8205S snap-mount gas valve (OEM #1172541) that meters 24V-controlled gas flow. A cracked, eroded, or no-glow igniter is the single most common cause of a furnace that clicks but never lights. These are genuine OEM parts engineered to the exact resistance, mounting, and voltage specifications of your furnace.

Specifications

Spec Value
Igniter Part Number 1172533 (Igniter HSI)
Flame Sensor Part Number 1172543 (Sensor Flame HSI)
Gas Valve Part Number 1172541 (Valve N HSI Snap HW VR8205S)
Type Hot Surface Igniter
Brand ICP / Heil / Tempstar
Control Voltage 24V
Fit OEM Direct Replacement

Compatibility

Engineered for the ICP/Heil/Tempstar X8MPN075B12A2 furnace and its closely related variants in the X8MPN075 platform. Always confirm your model and serial label before ordering. These OEM ignition components fit the original mounting bracket and harness, so no adapters or rewiring are required.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, and shut off the gas. Verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph all wiring and the igniter/sensor/valve positions before disconnecting.
  4. Remove — Unplug the igniter and flame sensor leads, unscrew their mounting brackets, and disconnect the gas valve wiring and union if replacing it. Handle the igniter only by its ceramic base — never touch the element.
  5. Install — Mount the new igniter and flame sensor in the original positions, reconnect per your photos, and torque the gas valve connections to spec; leak-check with soap solution.
  6. Test — Restore gas and power, run a heat cycle, and confirm the igniter glows, burners light, and the flame sensor proves flame within seconds.

Signs You Need a Replacement

  • Igniter does not glow or shows visible cracks/erosion on the element.
  • Furnace clicks and the inducer runs, but burners never light.
  • Burners light then shut off after a few seconds (weak or dirty flame sensor).
  • Short-cycling or repeated ignition lockouts on the control board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP X8MPN075B12A2 — Silicon Nitride HSI | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP X8MPN075B12A2 — Silicon Nitride HSI | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP X8MPN075B12A2 — Silicon Nitride HSI | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online