Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for WFMR110C066B1 — Includes Bracket & HSI | Ships Today
ICP

ICP Hot Surface Igniter Kit for WFMR110C066B1 — Includes Bracket & HSI | Ships Today

SKU: 1183455 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter assembly is the factory ignition component for the ICP / Tempstar / Heil WFMR110C066B1 gas furnace. The hot surface igniter (HSI) glows to roughly 2,500°F when the control board calls for heat, igniting the gas as it leaves the burners. This kit covers the full ignition group: OEM igniter 1176919, igniter mounting bracket 1183455, and the HSI snap-on valve harness 1176929 (36J24618). A cracked, eroded, or open igniter is the most common cause of "no heat" no-light calls. Igniters are brittle silicon nitride/carbide elements that wear with every heating cycle, making replacement routine maintenance on high-cycling furnaces.

Specifications

Spec Value
Part Numbers 1176919, 1183455, 1176929
Type Hot Surface Igniter (HSI)
Brand ICP / Tempstar / Heil
Voltage 120V
Includes Igniter, Mounting Bracket, Snap Valve Harness
Application Gas Furnace

Compatibility

Engineered as a direct OEM-fit replacement for the ICP-family WFMR110C066B1 furnace and shared platform models sold under the Tempstar, Heil, Comfortmaker, and Arcoaire brands. Always confirm against your unit's rating plate before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, and shut off the gas. Verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner/service panel.
  3. Document — Photograph the igniter wiring and bracket position before disconnecting.
  4. Remove — Unplug the igniter harness, remove the bracket screw, and lift out the old igniter. Handle only by the ceramic base — never touch the silicon element.
  5. Install — Mount the new igniter on the bracket, set the correct flame position, and reconnect the harness per your photo.
  6. Test — Restore gas and power, run a heat cycle, and confirm the igniter glows and the burners light cleanly.

Signs You Need a Replacement

  • Furnace blower runs but no heat / burners never light
  • Igniter shows visible cracks, blistering, or white hot spots
  • Repeated lockouts after several ignition attempts
  • No glow visible through the sight port during a heat call

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP WFMR110C066B1 — Includes Bracket & HSI | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP WFMR110C066B1 — Includes Bracket & HSI | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP WFMR110C066B1 — Includes Bracket & HSI | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online