Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for WFML090B042B3 – HSI with Bracket | Ships Today
ICP

ICP Hot Surface Igniter Kit for WFML090B042B3 – HSI with Bracket | Ships Today

SKU: 1183455 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (HSI) assembly for the ICP / Heil / Tempstar WFML090B042B3 gas furnace includes the igniter element (part 1176919), its mounting bracket (part 1183455), and the matched HSI hardware referenced by part 1176929 (HSI snap, ref 36J24618). The hot surface igniter glows red-hot on each heat call to ignite the main burners, replacing the older standing-pilot and spark systems. HSIs are the single most common furnace failure point: the brittle silicon-carbide/nitride element cracks from thermal cycling, contamination, or being touched by bare hands. When it fails, the furnace draft inducer and gas valve sequence normally but the burners never light, producing a no-heat / lockout condition.

Specifications

Spec Value
Part Numbers 1176919 (igniter), 1183455 (bracket), 1176929 (HSI snap, ref 36J24618)
Type Hot Surface Igniter (HSI)
Brand ICP (Heil / Tempstar / Comfortmaker)
Includes Igniter element + mounting bracket + hardware
Fitment OEM replacement

Compatibility

Designed for the ICP/Heil/Tempstar WFML090B042B3 furnace and related WFML-series / ICP-family units using this hot surface igniter and bracket combination. Match the igniter and bracket style to your existing assembly before installing.

Installation Guide

  1. Safety First – Disconnect power at the furnace switch and breaker, shut off the gas, and verify zero voltage with a multimeter.
  2. Access – Remove the burner-compartment service panel.
  3. Document – Photograph the igniter position, bracket, and wiring connector before removal.
  4. Remove – Unplug the igniter connector and unscrew the bracket; lift the fragile element out without touching the ceramic.
  5. Install – Mount the new igniter on its bracket, set it in the factory location over the burner, and reconnect the plug — handle by the base only.
  6. Test – Restore gas and power, then run a heat call and confirm the igniter glows and burners light within the trial-for-ignition period.

Signs You Need a Replacement

  • Igniter no longer glows on a heat call.
  • Furnace locks out with no burner ignition after the inducer runs.
  • Visible crack, blistering, or break in the ceramic element.
  • Open circuit / no continuity when the cold igniter is ohm-tested.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP WFML090B042B3 – HSI with Bracket | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP WFML090B042B3 – HSI with Bracket | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP WFML090B042B3 – HSI with Bracket | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online