Overview

This OEM hot surface igniter assembly (ICP igniter 1176919 with mounting bracket 1183455) is the ignition source for the ICP / Heil / Tempstar WFML070A036B3 gas furnace. On a call for heat, the control board energizes the igniter; it glows white-hot to light the gas at the burners. Hot surface igniters are brittle and degrade over thousands of cycles, making them one of the most frequently replaced furnace parts. A cracked or open igniter produces the classic no-heat symptom: the inducer runs, the gas valve waits, but the burners never light and the furnace locks out. This listing covers the igniter and its bracket; related snap-disc / valve hardware (1176929) for this model is sold separately.

Specifications

Spec Value
Part Number 1176919 (igniter), 1183455 (bracket)
Type Hot Surface Igniter (HSI)
Brand ICP / Heil / Tempstar
Element Silicon carbide / nitride glow element
Includes Igniter + mounting bracket
Fitment OEM exact-fit

Compatibility

Designed for the ICP / Heil / Tempstar WFML070A036B3 gas furnace and other ICP-family furnaces using this HSI and bracket. Match the connector and bracket profile to your existing igniter before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter and shut the gas if servicing nearby components.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter position, bracket, and wire routing before disconnecting.
  4. Remove — Unplug the igniter connector, unscrew the bracket, and lift the assembly out. Never touch the glow element with bare fingers.
  5. Install — Mount the new igniter and bracket in the original position, confirm proper alignment over the burner, and reconnect the lead.
  6. Test — Restore power and gas, run a heat call, and confirm the igniter glows and the burners light.

Signs You Need a Replacement

  • Inducer runs but burners never ignite
  • Igniter does not glow, or glows weakly
  • Visible crack, chip, or white-spot damage on the element
  • Furnace lockout after several failed ignition attempts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP WFML070A036B3 — OEM 1176919 with Bracket | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP WFML070A036B3 — OEM 1176919 with Bracket | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP WFML070A036B3 — OEM 1176919 with Bracket | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.