Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for WFML070A036B2 — HSI w/ Bracket | Ships Today
ICP

ICP Hot Surface Igniter Kit for WFML070A036B2 — HSI w/ Bracket | Ships Today

SKU: 1183455 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter assembly for the ICP Tempstar Heil WFML070A036B2 furnace includes the igniter (part #1176919), its mounting bracket (part #1183455), and the matching HSI snap valve component (part #1176929, ref 36J24618). The hot surface igniter glows red-hot on each call for heat to ignite the burners. It is the single most common furnace ignition failure point — repeated heating and cooling cycles eventually crack the fragile element, leaving you with a furnace that clicks, attempts to light, but produces no flame and locks out. Installing the OEM igniter with its correct bracket ensures proper gap and alignment to the burner.

Specifications

Spec Value
Igniter Part Number 1176919
Bracket Part Number 1183455
HSI Valve/Snap 1176929 (36J24618)
Type Hot Surface Igniter (HSI)
Brand ICP / Tempstar / Heil
Application Gas Furnace Ignition

Compatibility

Designed for the ICP Tempstar Heil WFML070A036B2 furnace and compatible ICP-family gas furnaces using this hot surface ignition system. Confirm your existing igniter style and bracket footprint before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter position, bracket orientation, and wiring before disconnecting.
  4. Remove — Unplug the igniter connector and unscrew the old igniter and bracket from the burner assembly. Handle by the ceramic base only — never touch the element.
  5. Install — Mount the new bracket and igniter, set the proper gap to the burner, and reconnect the wiring per your photo.
  6. Test — Restore power, initiate a heat call, and confirm the igniter glows and burners light cleanly.

Signs You Need a Replacement

  • Igniter no longer glows on a call for heat.
  • Visible cracks or breaks in the ceramic element.
  • Furnace clicks and attempts ignition but fails to light, then locks out.
  • Short-cycling with no burner flame established.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP WFML070A036B2 — HSI w/ Bracket | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP WFML070A036B2 — HSI w/ Bracket | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP WFML070A036B2 — HSI w/ Bracket | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.