Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for WFML045A024B3 — With Bracket | Ships Today
ICP

ICP Hot Surface Igniter Kit for WFML045A024B3 — With Bracket | Ships Today

SKU: 1183455 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (part number 1176919) with its matched mounting bracket (1183455) is the ignition source for the ICP / Heil / Tempstar WFML045A024B3 gas furnace. On a call for heat the control board energizes the igniter, which glows red-hot to light the burners. Hot surface igniters are brittle and wear out over time — micro-cracks, carbon buildup, and thermal fatigue eventually stop them from reaching ignition temperature, leaving you with a furnace that cycles, clicks, but never lights. This is the single most common no-heat failure on modern gas furnaces. Installing a fresh OEM igniter and bracket restores fast, reliable ignition. A compatible White-Rodgers 36J24618 snap-on HSI gas valve (part 1176929) is also referenced for this model for technicians servicing the full ignition assembly.

Specifications

Spec Value
Igniter Part Number 1176919
Bracket Part Number 1183455
Related Valve Reference 1176929 (HSI snap, WR 36J24618)
Type Hot surface igniter
Brand ICP / Heil / Tempstar / Comfortmaker
Fit OEM direct replacement

Compatibility

Designed for the ICP WFML045A024B3 furnace and other Heil, Tempstar, Comfortmaker, and Arcoaire models using this hot surface igniter and bracket. Handle the igniter element by the ceramic base only — never touch the glow element.

Installation Guide

  1. Safety First — Shut off gas and electrical power, then verify zero voltage at the igniter leads with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter position and wiring relative to the burners before removal.
  4. Remove — Unplug the igniter harness and unscrew the old igniter and bracket; discard carefully (the element is fragile).
  5. Install — Mount the new bracket and igniter at the factory gap from the burner, handling only the ceramic base, then reconnect the harness.
  6. Test — Restore gas and power and confirm the igniter glows and lights the burners on the first ignition attempt.

Signs You Need a Replacement

  • Furnace clicks and cycles but burners never light
  • Igniter shows cracks, blisters, or no longer glows
  • Repeated ignition lockouts after multiple tries
  • Visible carbon buildup or a fractured glow element

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP WFML045A024B3 — With Bracket | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP WFML045A024B3 — With Bracket | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP WFML045A024B3 — With Bracket | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online