Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for WFAR100C048C1 — Includes Igniter Bracket | Ships Today
ICP

ICP Hot Surface Igniter Kit for WFAR100C048C1 — Includes Igniter Bracket | Ships Today

SKU: 1184324 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter kit is the factory-correct ignition component for the ICP/Tempstar/Heil WFAR100C048C1 gas furnace. The kit includes igniter element 1176919 and igniter mounting bracket 1184324, giving you everything needed for a complete, drop-in replacement. The hot surface igniter (HSI) glows to roughly 2,000°F when the control board calls for heat, lighting the gas at the burner. When an igniter cracks, weakens, or burns out, the furnace will fail to light, short-cycle, or lock out after several failed ignition attempts. Because the silicon carbide (or silicon nitride) element is brittle, the matched bracket ensures correct alignment in the burner flame path so the new igniter reaches and lights the gas reliably.

Specifications

Spec Value
Part Numbers 1176919 (Igniter), 1184324 (Bracket)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Fit OEM Direct Replacement
Application Gas Furnace Ignition
Voltage 120V

Compatibility

Engineered specifically for the ICP/Tempstar/Heil model WFAR100C048C1 furnace and shared platform models from Comfortmaker and other ICP family brands using the same burner assembly. Always confirm your existing igniter and bracket part numbers before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter and shut off the gas supply.
  2. Access — Remove the furnace service / burner compartment panel.
  3. Document — Photograph the igniter wiring and bracket position before disconnecting.
  4. Remove — Unplug the igniter connector, unscrew the bracket, and carefully withdraw the old igniter without touching the element.
  5. Install — Mount the new igniter on bracket 1184324, position it in the burner flame path per your photo, and reconnect the harness. Handle the element by the ceramic base only.
  6. Test — Restore gas and power, then run a heat cycle and confirm the igniter glows and lights the burners.

Signs You Need a Replacement

  • Furnace clicks and tries to start but never lights
  • Igniter does not glow or glows dimly/unevenly
  • Visible cracks, blistering, or white spots on the element
  • Control board lockout after 3+ failed ignition attempts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP WFAR100C048C1 — Includes Igniter Bracket | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP WFAR100C048C1 — Includes Igniter Bracket | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP WFAR100C048C1 — Includes Igniter Bracket | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online