Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for WFAR080B048C1 — With Bracket | Ships Today
ICP

ICP Hot Surface Igniter Kit for WFAR080B048C1 — With Bracket | Ships Today

SKU: 1184324 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (part #1176919) and its matching mounting bracket (part #1184324) ignite the gas burners on your ICP WFAR080B048C1 furnace. On a call for heat, the control board energizes the igniter, which glows white-hot to light the main burners. Hot surface igniters are brittle silicon-carbide or silicon-nitride elements that crack and degrade over time. A failed igniter is one of the most common causes of no-heat calls: the inducer runs, the gas valve clicks, but the burners never light and the furnace locks out. Replacing the igniter — along with the bracket that holds it in precise alignment with the burner — restores reliable ignition.

Specifications

Spec Value
OEM Part Numbers 1176919 (Igniter), 1184324 (Igniter Bracket)
Type Hot Surface Igniter
Brand ICP (Tempstar / Heil)
Application Gas Furnace Burner Ignition
Includes Igniter + Mounting Bracket

Compatibility

Directly fits the ICP / Tempstar / Heil WFAR080B048C1 gas furnace. The igniter and bracket are matched components for this furnace family — installing both ensures correct positioning over the burner for clean, repeatable ignition.

Installation Guide

  1. Safety First — Shut off gas and disconnect power, then verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter wiring and bracket position before removing.
  4. Remove — Unplug the igniter connector and unscrew the old igniter and bracket. Handle the ceramic element only by its body, never the hot surface.
  5. Install — Mount the new bracket and igniter, aligning the element over the burner per your photo, then reconnect the plug.
  6. Test — Restore gas and power and verify the igniter glows and burners light on a heat call.

Signs You Need a Replacement

  • Furnace ignites no flame and locks out after several attempts
  • Igniter visibly cracked, chipped, or no longer glowing
  • Inducer and gas valve cycle but burners never light
  • Intermittent no-heat that worsens over time

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP WFAR080B048C1 — With Bracket | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP WFAR080B048C1 — With Bracket | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP WFAR080B048C1 — With Bracket | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.