Overview

This OEM ICP hot surface igniter kit includes the igniter (part number 1176919) and its mounting bracket (part number 1184324) for the ICP / Tempstar / Heil WFAR060B048C1 gas furnace. The hot surface igniter glows to roughly 2,000°F on a call for heat to light the gas at the burners. It is one of the most failure-prone parts in a modern furnace — the brittle element cracks from thermal cycling and eventually stops glowing. When it fails you get no ignition: the inducer runs, the gas valve may click, but the burners never light, and the control board usually locks out after several failed attempts.

Specifications

Spec Value
Igniter Part Number 1176919
Bracket Part Number 1184324
Type Hot Surface Igniter
Brand ICP (Tempstar / Heil / Comfortmaker)
Voltage 120V
Fitment OEM Direct Replacement

Compatibility

Direct OEM fit for the ICP / Tempstar / Heil WFAR060B048C1 gas furnace. The 1176919 igniter and 1184324 bracket are used across many ICP-family furnaces built on the same burner assembly. Confirm your furnace uses a 120V hot surface igniter (not a spark or silicon-nitride mini igniter) before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker and verify zero voltage with a multimeter before proceeding.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter position, bracket orientation, and wire routing before removing anything.
  4. Remove — Unplug the igniter connector and remove the mounting screw(s) holding the igniter and bracket. Handle only by the ceramic base — never touch the fragile element.
  5. Install — Mount the new bracket and igniter, align the element over the burner per your photo, and reconnect the plug.
  6. Test — Restore power and confirm the igniter glows bright orange and the burners light within the trial-for-ignition period.

Signs You Need a Replacement

  • Igniter does not glow on a call for heat
  • Burners fail to light and the furnace locks out
  • Visible crack, blister, or white spot on the igniter element
  • Furnace short-cycles or only heats intermittently

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP WFAR060B048C1 — OEM 1176919 with Bracket | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP WFAR060B048C1 — OEM 1176919 with Bracket | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP WFAR060B048C1 — OEM 1176919 with Bracket | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online