Overview

This genuine ICP hot surface igniter kit includes the igniter (OEM #1171306) and its matched wiring harness kit (OEM #1188370) for the RGS150SRCA0AAAA furnace. On each call for heat, the control board sends voltage to the igniter, which glows white-hot and ignites the gas at the burners. Because the igniter element is thin and brittle, it is one of the most common furnace failure points — it degrades with thermal cycling and cracks easily if touched or contaminated. The included wiring kit ensures a clean, corrosion-free connection to the harness, eliminating the intermittent no-heat faults that come from a brittle or burned igniter lead. Replacing both together is the reliable, professional repair.

Specifications

Spec Value
Igniter Part Number 1171306
Wiring Kit Part Number 1188370
Type Hot surface igniter with wiring harness
Brand ICP (Heil / Tempstar / Comfortmaker)
Function Ignites burners on heat call
Fitment OEM exact-fit

Compatibility

Designed for the ICP / Heil / Tempstar / Comfortmaker RGS150SRCA0AAAA furnace and related models that use this hot surface igniter and harness. Match the igniter mounting bracket and connector to your existing part before ordering.

Installation Guide

  1. Safety First – Shut off gas at the manual shutoff and disconnect electrical power. Verify zero voltage at the igniter leads with a multimeter before working.
  2. Access – Remove the burner compartment door to reach the igniter at the burner assembly.
  3. Document – Photograph the igniter position, bracket, and wiring/connector routing before removal.
  4. Remove – Unplug the harness, unfasten the igniter bracket screw, and carefully withdraw the old igniter — never touch the new element with bare fingers.
  5. Install – Mount the new igniter in the same position, install the new wiring kit, and seat the connector fully.
  6. Test – Restore gas and power, initiate a heat call, and confirm the igniter glows and the burners light within the normal trial-for-ignition window.

Signs You Need a Replacement

  • Furnace blower runs but burners never light (no heat)
  • Visible crack, blistering, or breakage in the igniter element
  • Igniter glows weakly or not at all on a heat call
  • Intermittent ignition lockouts or repeated retry cycling

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS150SRCA0AAAA – With Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS150SRCA0AAAA – With Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS150SRCA0AAAA – With Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online