Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS150SFCA0AAAA — OEM 1171306 with Wiring | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS150SFCA0AAAA — OEM 1171306 with Wiring | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM hot surface igniter (part number 1171306) bundled with the matching igniter wiring kit (part number 1188370) for the ICP Tempstar Heil RGS150SFCA0AAAA gas furnace. The hot surface igniter is the component that glows red-hot on each call for heat, lighting the gas at the burners. Igniters are a wear item — the silicon carbide or silicon nitride element becomes brittle with every heating cycle and eventually cracks or fails open. When the igniter fails, the furnace blower may run but never produce heat, often locking out after several failed ignition attempts. Replacing the igniter along with its wiring harness ensures clean electrical contact and reliable startup.

Specifications

Spec Value
Part Number 1171306 (Igniter)
Included Part 1188370 (Wiring Kit, Igniter)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Fits Model RGS150SFCA0AAAA
Application Gas Furnace Ignition
Fit Direct OEM Replacement

Compatibility

Direct-fit replacement for the ICP Tempstar Heil RGS150SFCA0AAAA. The igniter and wiring kit are used across related ICP-family gas furnaces (Tempstar, Heil, Comfortmaker, Arcoaire, KeepRite) built on the same ignition platform. Confirm part numbers 1171306 and 1188370 against your furnace parts list before ordering.

Installation Guide

  1. Safety First — Shut off the gas and disconnect electrical power. Verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner compartment service panel.
  3. Document — Photograph the igniter position and the wiring connection at the harness and control board.
  4. Remove — Unplug the igniter harness, then carefully unfasten and remove the old igniter — handle by the ceramic base only, never the fragile element.
  5. Install — Mount the new igniter in the same position, route and connect the new wiring kit, and avoid touching the element with bare fingers.
  6. Test — Restore gas and power, then watch a full ignition cycle to confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • No heat — blower runs but burners never light
  • Furnace locks out after repeated failed ignition attempts
  • Igniter element is cracked, broken, or no longer glows
  • Visible damage or corrosion at the igniter wiring connector

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS150SFCA0AAAA — OEM 1171306 with Wiring | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS150SFCA0AAAA — OEM 1171306 with Wiring | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS150SFCA0AAAA — OEM 1171306 with Wiring | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online