Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS150SFBA0AGAA — Includes Igniter Wiring Harness | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS150SFBA0AGAA — Includes Igniter Wiring Harness | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter assembly is the direct ignition source for the ICP/Tempstar/Heil RGS150SFBA0AGAA gas furnace. The igniter (OEM 1171306) glows to a high temperature on each call for heat to light the main burners, while the included igniter wiring kit (OEM 1188370) replaces the brittle, heat-fatigued harness that connects it to the control board. A failed or cracked igniter is one of the most common causes of no-heat calls: the element develops hairline fractures, loses continuity, and the furnace locks out after several failed ignition attempts. Replacing the igniter together with its wiring kit restores reliable, single-try ignition and prevents repeat callbacks from a marginal connector.

Specifications

Spec Value
OEM Part Number (Igniter) 1171306
OEM Part Number (Wiring Kit) 1188370
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Application Gas Furnace Direct Ignition
Fits Model RGS150SFBA0AGAA

Compatibility

Engineered for the ICP-family RGS150SFBA0AGAA furnace and the closely related Tempstar, Heil, and Comfortmaker variants that share the same ignition platform. Always confirm your existing igniter's part number and connector before ordering. This is the OEM-specified replacement, not a universal substitute.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, shut off the gas, and verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter mounting position and the wiring harness routing before disconnecting anything.
  4. Remove — Unplug the igniter connector, remove the mounting screw(s), and lift the old igniter out by its ceramic base — never touch the element. Cut or unplug the old harness.
  5. Install — Mount the new igniter in the exact original position so the element sits in the burner flame path, then connect the new wiring kit per your photo.
  6. Test — Restore gas and power and watch a full ignition cycle: the igniter should glow bright and light the burners on the first try.

Signs You Need a Replacement

  • Furnace clicks and tries to light but never ignites, then locks out.
  • Igniter shows visible cracks, blisters, or no longer glows.
  • Repeated ignition retries before the burners finally catch.
  • Melted, discolored, or loose igniter connector and harness.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS150SFBA0AGAA — Includes Igniter Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS150SFBA0AGAA — Includes Igniter Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS150SFBA0AGAA — Includes Igniter Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online