Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS150SEBA0AGAA — With Wiring Harness | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS150SEBA0AGAA — With Wiring Harness | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM hot surface igniter (part 1171306) paired with its dedicated igniter wiring kit (part 1188370) for the ICP / Tempstar / Heil RGS150SEBA0AGAA gas unit. On each call for heat the control board energizes the igniter, which heats to a glowing temperature and lights the burner gas. The wiring kit supplies the correct connector, leads, and ceramic-rated terminals to power the igniter safely. Hot surface igniters are brittle and degrade with every heating cycle; the silicon-carbide or silicon-nitride element eventually cracks, thins, or simply fails to reach ignition temperature. When the igniter fails, the furnace runs its sequence but never lights — leading to no heat and lockout. Replacing the igniter together with a fresh wiring kit eliminates intermittent connector and lead failures that can mimic a bad igniter.

Specifications

Spec Value
Part Numbers 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter
Brand ICP (Tempstar / Heil)
Includes Igniter element and igniter wiring harness kit
Function Burner ignition on call for heat
Fits Model RGS150SEBA0AGAA
Fitment OEM direct replacement

Compatibility

Engineered for the ICP / Tempstar / Heil RGS150SEBA0AGAA and related RGS150 platform units using the same hot surface ignition system. Confirm your full model and serial number before ordering.

Installation Guide

  1. Safety First — Shut off gas and disconnect power. Verify zero voltage with a multimeter before working in the burner compartment.
  2. Access — Remove the burner/ignition access panel.
  3. Document — Photograph the igniter position and wiring connector before disconnecting.
  4. Remove — Unplug the harness, remove the igniter mounting screw, and carefully withdraw the brittle igniter — never touch the element with bare fingers.
  5. Install — Mount the new 1171306 igniter, install the 1188370 wiring kit, and seat the connector fully.
  6. Test — Restore gas and power, call for heat, and confirm the igniter glows and the burners light within the normal sequence.

Signs You Need a Replacement

  • Furnace runs the ignition sequence but burners never light
  • Visible cracks or breaks in the igniter element
  • Igniter glows weakly or not at all
  • Repeated ignition lockouts and no-heat calls

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS150SEBA0AGAA — With Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS150SEBA0AGAA — With Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS150SEBA0AGAA — With Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online