Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS150SEBA0AAAA — OEM Ignitor + Wiring Harness | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS150SEBA0AAAA — OEM Ignitor + Wiring Harness | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM Hot Surface Igniter Kit pairs the igniter (part number 1171306) with its matching wiring harness kit (part number 1188370) for the ICP / Tempstar / Heil RGS150SEBA0AAAA gas-electric package unit. On a heat call, the control board sends voltage to the igniter, which glows red-hot and lights the burners. Hot surface igniters are brittle and degrade with every heating cycle — hairline cracks and erosion eventually cause an open circuit and no heat. The included wiring kit ensures clean, factory-spec terminations so the igniter receives correct voltage. Installing the complete OEM kit restores reliable first-try ignition and prevents nuisance lockouts.

Specifications

Spec Value
Igniter Part Number 1171306
Wiring Kit Part Number 1188370
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Includes Igniter + wiring harness kit
Fitment OEM exact replacement
Application Gas furnace / rooftop package unit

Compatibility

Direct OEM replacement ignition kit for the ICP Tempstar Heil RGS150SEBA0AAAA package unit. The igniter (1171306) and wiring kit (1188370) are matched to this model's ignition circuit and mounting. Confirm your existing igniter part number before ordering.

Installation Guide

  1. Safety First — Disconnect electrical power and shut off the gas. Verify zero voltage with a multimeter before proceeding.
  2. Access — Remove the burner/ignition access panel to expose the igniter and its harness.
  3. Document — Photograph the igniter mounting position, bracket orientation, and wiring connection before removal.
  4. Remove — Disconnect the harness plug and remove the igniter mounting screw(s). Handle the old igniter by the ceramic base only.
  5. Install — Mount the new igniter without touching the silicon element, install the new wiring kit, and reconnect per your photo.
  6. Test — Restore gas and power, start a heat cycle, and confirm the igniter glows and lights the burners on the first attempt.

Signs You Need a Replacement

  • No heat — igniter never glows on a heat call
  • Visible cracks, chips, or white/eroded spots on the element
  • Furnace locks out after several failed ignition attempts
  • Igniter glows but burners fail to light, or harness is brittle/burned

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS150SEBA0AAAA — OEM Ignitor + Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS150SEBA0AAAA — OEM Ignitor + Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS150SEBA0AAAA — OEM Ignitor + Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online