Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS150LTCB0AAAA — OEM 1171306 with Wiring | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS150LTCB0AAAA — OEM 1171306 with Wiring | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM hot surface igniter (factory part number 1171306, IGNITOR) for the ICP / Tempstar / Heil RGS150LTCB0AAAA is paired with its matching wiring harness kit (1188370, WIRING KIT IGNITER) for a complete, clean replacement. On a call for heat, the control board sends voltage to the igniter, which glows red-hot and lights the burners. The igniter element is brittle and degrades with every heating cycle until it cracks or no longer reaches ignition temperature — the most common reason a furnace blows cold air or short-cycles on a failed ignition. Including the wiring kit ensures fresh connectors and leads, eliminating high-resistance terminals that prematurely kill the new igniter.

Specifications

Spec Value
Part Numbers 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot surface igniter
Includes Igniter element + igniter wiring kit
Brand ICP (Tempstar / Heil)
Fits Model RGS150LTCB0AAAA
Application Gas furnace burner ignition
Fitment OEM exact replacement

Compatibility

Direct-fit OEM replacement for the ICP / Tempstar / Heil RGS150LTCB0AAAA gas furnace and shared-platform models using this igniter and harness. Handle the ceramic element by the body only — skin oils shorten its life. Confirm the part numbers against your unit before installing.

Installation Guide

  1. Safety First — Shut off gas and electrical power; verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment door to reach the igniter near the burners.
  3. Document — Photograph the igniter position, bracket, and wiring routing.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and withdraw the cracked igniter.
  5. Install — Mount the new igniter (touching only the body), then connect it with the new wiring kit.
  6. Test — Restore gas and power, call for heat, and watch the igniter glow and light the burners.

Signs You Need a Replacement

  • Furnace blows cold air — igniter never glows
  • Visible crack or break in the ceramic element
  • Short cycling or repeated ignition lockouts
  • Igniter glows weakly or fails to reach ignition temperature

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS150LTCB0AAAA — OEM 1171306 with Wiring | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS150LTCB0AAAA — OEM 1171306 with Wiring | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS150LTCB0AAAA — OEM 1171306 with Wiring | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online