Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS150LTCA0AAAA — OEM 1171306 with Wiring | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS150LTCA0AAAA — OEM 1171306 with Wiring | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM hot surface igniter kit for the ICP / Tempstar / Heil RGS150LTCA0AAAA gas furnace, including igniter part number 1171306 and the matching wiring kit 1188370. On a heat call, the control board energizes the igniter; its element heats to a glowing hot surface that lights the gas at the burners. Hot surface igniters are brittle and wear out — micro-cracks, contamination from oily fingerprints, and normal aging all lead to failure. A bad igniter is one of the most common no-heat causes: the furnace tries to ignite, fails, and locks out. The included wiring kit ensures a clean, correct electrical connection.

Specifications

Spec Value
Part Numbers 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter Kit
Brand ICP (Tempstar / Heil / Comfortmaker)
Fits Model RGS150LTCA0AAAA
Application Gas furnace burner ignition
Fitment OEM replacement

Compatibility

Fits the ICP-family RGS150LTCA0AAAA and the related RGS150 platform sold under Tempstar, Heil, and Comfortmaker. Verify OEM numbers 1171306 and 1188370 against your furnace before ordering.

Installation Guide

  1. Safety First — Disconnect power to the furnace and verify zero voltage with a multimeter.
  2. Access — Remove the burner/service panel to reach the igniter at the burner assembly.
  3. Document — Photograph the igniter position, bracket, and wiring/connector routing.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and withdraw the old igniter — handle the new element by its base only, never the ceramic/element.
  5. Install — Mount the new igniter so it sits correctly in the flame path, install the included wiring kit, and connect per your photo.
  6. Test — Restore power, call for heat, and confirm the igniter glows and lights the burners cleanly.

Signs You Need a Replacement

  • No heat — furnace tries to light, fails, and locks out
  • Igniter does not glow on a heat call
  • Visible cracks, blistering, or breakage in the igniter element
  • Repeated ignition-failure fault codes from the control board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS150LTCA0AAAA — OEM 1171306 with Wiring | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS150LTCA0AAAA — OEM 1171306 with Wiring | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS150LTCA0AAAA — OEM 1171306 with Wiring | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online