Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS150LFAA0AAAA - With Wiring Harness | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS150LFAA0AAAA - With Wiring Harness | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter assembly fits the ICP/Tempstar/Heil RGS150LFAA0AAAA gas furnace and includes both the igniter element (part number 1171306) and the matching igniter wiring kit (part number 1188370). The hot surface igniter is energized by 120V at the start of each heating cycle, glowing white-hot to light the burners. These ceramic elements are brittle and degrade with every thermal cycle, eventually cracking or losing the ability to reach ignition temperature. When the igniter fails the furnace will not light, producing a no-heat condition that typically locks out after several failed ignition attempts.

Specifications

Spec Value
Part Numbers 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot Surface Igniter
Brand ICP (Tempstar / Heil / Comfortmaker)
Operating Voltage 120 VAC
Includes Igniter element + wiring harness kit
Fit OEM Replacement

Compatibility

Designed as the factory igniter replacement for ICP model RGS150LFAA0AAAA and equivalent furnaces marketed under the Tempstar, Heil, Comfortmaker, Arcoaire and KeepRite brands. The included wiring kit ensures a clean, correct connection to the furnace control board.

Installation Guide

  1. Safety First - Shut off gas and electric power to the furnace, then verify zero voltage at the igniter leads with a multimeter.
  2. Access - Remove the furnace burner-compartment service panel.
  3. Document - Photograph the igniter mounting position and wiring routing before disconnecting.
  4. Remove - Unplug the igniter harness and remove the mounting screw, handling the old element by its bracket only.
  5. Install - Mount the new igniter without touching the ceramic surface, install the wiring kit, and connect to the control board.
  6. Test - Restore gas and power, start a heat cycle, and confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • Furnace blower runs but burners never light (no heat).
  • Igniter does not glow at the start of the heating sequence.
  • Furnace locks out after three failed ignition attempts.
  • Visible cracks, blistering, or breaks in the ceramic igniter element.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS150LFAA0AAAA - With Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS150LFAA0AAAA - With Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS150LFAA0AAAA - With Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online