Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS150LECB0AAAA — OEM 1171306 with Wiring | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS150LECB0AAAA — OEM 1171306 with Wiring | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM hot surface igniter (part number 1171306), paired with the matching igniter wiring kit (part number 1188370), is the ignition source for the ICP RGS150LECB0AAAA gas furnace. On each call for heat, the control board energizes the igniter, which glows red-hot to ignite the gas at the burners. Hot surface igniters are brittle and degrade with every heating cycle, so they are the single most common furnace no-heat failure. The included wiring kit ensures a clean, correct connection — eliminating the cracked or corroded harness that often accompanies an aged igniter. If your furnace blower runs but never produces heat, a failed igniter is the first suspect.

Specifications

Spec Value
Part Numbers 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot Surface Igniter
Includes Igniter element and igniter wiring kit
Brand ICP / Tempstar / Heil / Comfortmaker
Fits Model RGS150LECB0AAAA
Application Gas Furnace Ignition
Fit OEM Genuine Replacement

Compatibility

Designed for the ICP RGS150LECB0AAAA and shared across many Tempstar, Heil, and Comfortmaker gas furnaces using this igniter and harness. Confirm your model and serial number on the furnace rating plate before ordering, and match the igniter mounting style to your existing part.

Installation Guide

  1. Safety First — Shut off gas and disconnect power, then verify zero voltage with a multimeter. Igniters are fragile — never touch the element with bare fingers.
  2. Access — Remove the furnace burner / control compartment panel.
  3. Document — Photograph the igniter position and wiring routing before disconnecting.
  4. Remove — Disconnect the old igniter harness and remove the mounting screw(s); discard the cracked element.
  5. Install — Mount the new igniter without touching the silicon nitride/carbide element, then connect the new wiring kit per your photos.
  6. Test — Restore gas and power, call for heat, and confirm the igniter glows and the burners light reliably.

Signs You Need a Replacement

  • Furnace blower runs but no heat is produced
  • Igniter does not glow on a call for heat
  • Visible cracks, chips, or white spots on the igniter element
  • Furnace ignites intermittently or locks out after several tries

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS150LECB0AAAA — OEM 1171306 with Wiring | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS150LECB0AAAA — OEM 1171306 with Wiring | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS150LECB0AAAA — OEM 1171306 with Wiring | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online