Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS150LDBA0AAAA — OEM Part 1171306 with Wiring | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS150LDBA0AAAA — OEM Part 1171306 with Wiring | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM hot surface igniter kit for the ICP / Tempstar / Heil RGS150LDBA0AAAA rooftop gas/electric package unit, including igniter part number 1171306 and igniter wiring kit 1188370. The hot surface igniter glows red-hot on a heat call to light the burners; the included wiring harness ensures a clean, correctly pinned connection to the control board. Hot surface igniters are brittle and degrade with every cycle, eventually cracking or losing the ability to reach ignition temperature — the most common cause of no-heat calls. This kit restores reliable, fast ignition.

Specifications

Spec Value
Igniter Part Number 1171306
Wiring Kit Part Number 1188370
Type Hot Surface Igniter
Brand ICP (Tempstar / Heil)
Includes Igniter + igniter wiring kit
Application Gas furnace ignition
Fit OEM exact-fit replacement
Model RGS150LDBA0AAAA

Compatibility

Designed for the ICP/Tempstar/Heil RGS150LDBA0AAAA and related RGS-series rooftop gas/electric units using this hot surface igniter and connector. Confirm igniter mounting and connector style against your original before ordering.

Installation Guide

  1. Safety First — Shut off gas, disconnect power, and verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter mounting position and harness routing to the control board.
  4. Remove — Unplug the igniter harness, remove the igniter mounting screw, and withdraw the old igniter without touching the element with bare fingers.
  5. Install — Mount the new igniter (handle by the ceramic base only), connect the new wiring kit, and route the harness clear of hot surfaces.
  6. Test — Restore gas and power, start a heat call, and confirm the igniter glows and burners light promptly.

Signs You Need a Replacement

  • No heat — igniter does not glow on a call
  • Visible cracks, chips, or white spots on the igniter element
  • Furnace locks out after several failed ignition attempts
  • Delayed ignition or rough light-off

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS150LDBA0AAAA — OEM Part 1171306 with Wiring | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS150LDBA0AAAA — OEM Part 1171306 with Wiring | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS150LDBA0AAAA — OEM Part 1171306 with Wiring | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online