Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Kit for RGS150HFBA0AAAA — OEM 1171306 + Wiring | Ships Today
ICP

ICP Hot Surface Igniter Kit for RGS150HFBA0AAAA — OEM 1171306 + Wiring | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM igniter kit for the ICP/Tempstar/Heil RGS150HFBA0AAAA includes the hot surface igniter (part #1171306) and the matching igniter wiring kit/harness (part #1188370). On each call for heat, the control board energizes the igniter, which glows red-hot to ignite gas at the burners. The igniter element is brittle and is one of the most common furnace failure points — it cracks from thermal cycling, contamination from oily fingerprints, or simple age. The included wiring kit ensures a clean, correct electrical connection and replaces brittle or heat-damaged igniter leads at the same time. Symptoms of a failed igniter include no ignition, repeated lockouts, or a furnace that clicks but never lights.

Specifications

Spec Value
Igniter Part Number 1171306
Wiring Kit Part Number 1188370
Type Hot surface igniter (HSI)
Brand ICP / Tempstar / Heil
Application Gas furnace burner ignition
Fitment OEM direct replacement

Compatibility

Designed for the ICP/Tempstar/Heil RGS150HFBA0AAAA gas furnace. The 1171306 igniter and 1188370 wiring kit are the factory-specified ignition components for this platform; verify both part numbers against your unit's parts list before ordering.

Installation Guide

  1. Safety First — Shut off gas and disconnect power. Verify zero voltage at the igniter leads with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter mounting and wire routing before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw(s), and withdraw the old igniter. Handle the new element by its ceramic base only — never touch the glow surface.
  5. Install — Mount the new igniter, install the new wiring kit, and connect per your photos, keeping leads clear of hot surfaces.
  6. Test — Restore gas and power, start a heat cycle, and confirm the igniter glows and burners light promptly.

Signs You Need a Replacement

  • No ignition / furnace clicks but won't light
  • Repeated ignition lockouts after several attempts
  • Visibly cracked, chipped, or broken igniter element
  • Igniter glows weakly or not at all

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS150HFBA0AAAA — OEM 1171306 + Wiring | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS150HFBA0AAAA — OEM 1171306 + Wiring | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS150HFBA0AAAA — OEM 1171306 + Wiring | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online